IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

74

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0109 # 09 Y:1997 09 1997 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING $69,563 $260,000 Not Implemented
AR0106 # 09 Y:1997 09 1997 INSTALL BACK-UP EQUIPMENT $60,000 $54,000 Not Implemented
AR0106 # 01 Y:1997 01 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,654 $690 Implemented
AR0106 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,804 $1,415 Implemented
AR0106 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $856 $0 Implemented
AR0106 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,478 $600 Not Implemented
AR0106 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,578 $350 Implemented
AR0106 # 06 Y:1997 06 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,942 $17,710 Not Implemented
AR0106 # 07 Y:1997 07 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $853 $0 Not Implemented
AR0106 # 08 Y:1997 08 1997 MINIMIZE WATER USAGE $616 $100 Implemented
AR0012 # 01 Y:1993 01 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,665 $1,170 Implemented
AR0012 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $1,684 $330 Not Implemented
AR0012 # 05 Y:1993 05 1993 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $23,430 $23,250 Not Implemented
AR0012 # 04 Y:1993 04 1993 OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS $1,373 $100 Not Implemented
AR0012 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $949 $720 Implemented
AR0012 # 02 Y:1993 02 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,387 $400 Implemented
LT0073 # 08 Y:1986 08 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,072 $596 Not Implemented
LT0073 # 07 Y:1986 07 1986 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $80,900 $4,000 Not Implemented
LT0073 # 06 Y:1986 06 1986 INSULATE BARE EQUIPMENT $269 $210 Not Implemented
LT0073 # 05 Y:1986 05 1986 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $3,840 $3,500 Not Implemented
LT0073 # 04 Y:1986 04 1986 INSTALL SET-BACK TIMERS $605 $3,500 Not Implemented
LT0073 # 03 Y:1986 03 1986 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $760 $0 Implemented
LT0073 # 02 Y:1986 02 1986 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $1,620 $0 Not Implemented
LT0073 # 01 Y:1986 01 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,670 $250 Not Implemented