Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
247
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0390 # 09 Y:2009 | 09 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,395 | $0 | Implemented |
WV0390 # 08 Y:2009 | 08 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,650 | $0 | Implemented |
WV0390 # 07 Y:2009 | 07 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,020 | $2,500 | Implemented |
WV0390 # 06 Y:2009 | 06 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,354 | $2,490 | Implemented |
WV0390 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,484 | $11,250 | Not Implemented |
WV0390 # 04 Y:2009 | 04 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $20,144 | $22,048 | Not Implemented |
WV0390 # 03 Y:2009 | 03 | 2009 | OPTIMIZE PLANT POWER FACTOR | $20,264 | $4,490 | Implemented |
WV0390 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,790 | $72,987 | Implemented |
WV0390 # 01 Y:2009 | 01 | 2009 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $138,137 | $122,000 | Not Implemented |
WV0366 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,342 | $0 | Implemented |
WV0366 # 03 Y:2007 | 03 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,515 | $540 | Not Implemented |
WV0366 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,238 | $5,148 | Implemented |
WV0366 # 05 Y:2007 | 05 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,696 | $1,315 | Implemented |
WV0366 # 06 Y:2007 | 06 | 2007 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $5,275 | $7,600 | Not Implemented |
WV0366 # 07 Y:2007 | 07 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,217 | $1,000 | Not Implemented |
WV0366 # 08 Y:2007 | 08 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,400 | $1,050 | Implemented |
WV0366 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,252 | $0 | Implemented |
WV0366 # 10 Y:2007 | 10 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $2,440 | $898 | Implemented |
WV0366 # 11 Y:2007 | 11 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,157 | $1,030 | Not Implemented |
WV0366 # 12 Y:2007 | 12 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,770 | $5,600 | Not Implemented |
WV0366 # 13 Y:2007 | 13 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,723 | $5,600 | Not Implemented |
WV0366 # 14 Y:2007 | 14 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,641 | $165 | Not Implemented |
WV0366 # 15 Y:2007 | 15 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $751 | $1,641 | Not Implemented |
WV0366 # 16 Y:2007 | 16 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $667 | $282 | Implemented |
WV0366 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,251 | $20,735 | Implemented |