Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
183
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0491 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $420 | $690 | Not Implemented |
KU0491 # 06 Y:1998 | 06 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $370 | $1,140 | Not Implemented |
KU0491 # 07 Y:1998 | 07 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $240 | $210 | Implemented |
KU0491 # 08 Y:1998 | 08 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,650 | $7,000 | Not Implemented |
KU0491 # 09 Y:1998 | 09 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,560 | $0 | Implemented |
KU0491 # 10 Y:1998 | 10 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $54,580 | $150,500 | Not Implemented |
KU0491 # 11 Y:1998 | 11 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $34,550 | $60,000 | Implemented |
MO0224 # 01 Y:1998 | 01 | 1998 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $7,972 | $20,000 | Implemented |
MO0224 # 02 Y:1998 | 02 | 1998 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $26,928 | $50,000 | Implemented |
MO0224 # 03 Y:1998 | 03 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $4,300 | $10,000 | Implemented |
MO0224 # 04 Y:1998 | 04 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,660 | $3,700 | Implemented |
MO0224 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,640 | $18,440 | Implemented |
MO0224 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $486 | $1,042 | Implemented |
MO0224 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $199 | $345 | Implemented |
MO0224 # 08 Y:1998 | 08 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $984 | $61 | Implemented |
MO0224 # 09 Y:1998 | 09 | 1998 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $5,439 | $10,327 | Implemented |
MO0224 # 10 Y:1998 | 10 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,064 | $0 | Implemented |
MO0224 # 11 Y:1998 | 11 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,200 | $747 | Not Implemented |
MO0139 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $37,079 | $35,142 | Not Implemented |
MO0139 # 02 Y:1995 | 02 | 1995 | USE RADIANT HEATER FOR SPOT HEATING | $23,442 | $62,400 | Not Implemented |
MO0139 # 03 Y:1995 | 03 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $822 | $2,276 | Not Implemented |
MO0139 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,914 | $6,490 | Not Implemented |
MO0139 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $895 | $576 | Not Implemented |
MO0139 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $816 | $202 | Not Implemented |
MO0139 # 07 Y:1995 | 07 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $741 | $2,789 | Not Implemented |