Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

144

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0127 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $718 $807 Implemented
WV0127 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,628 $4,080 Implemented
WV0127 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $243 $480 Implemented
WV0127 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $391 $200 Implemented
WV0127 # 05 Y:1997 05 1997 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $19,644 $12,500 Not Implemented
WV0127 # 06 Y:1997 06 1997 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,192 $0 Not Implemented
WV0127 # 07 Y:1997 07 1997 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $96,588 $16,000 Not Implemented
WV0127 # 08 Y:1997 08 1997 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $538 $188 Not Implemented
WV0127 # 09 Y:1997 09 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,040 $200 Not Implemented
WV0127 # 10 Y:1997 10 1997 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $85,710 $80,000 Not Implemented
HO0159 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,357 $5,548 Not Implemented
HO0159 # 02 Y:1997 02 1997 INSTALL OCCUPANCY SENSORS $787 $600 Implemented
HO0159 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $296 $20 Implemented
HO0159 # 04 Y:1997 04 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $4,080 $6,500 Not Implemented
HO0159 # 05 Y:1997 05 1997 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $3,070 $0 Not Implemented
HO0159 # 06 Y:1997 06 1997 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $1,920 $500 Not Implemented
WV0076 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,723 $2,483 Implemented
WV0076 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,292 $3,720 Implemented
WV0076 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $494 $400 Implemented
WV0076 # 04 Y:1996 04 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,347 $35 Implemented
WV0076 # 05 Y:1996 05 1996 USE SYNTHETIC LUBRICANT $360 $775 Not Implemented
WV0076 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $557 $85 Not Implemented
WV0076 # 07 Y:1996 07 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,461 $2,640 Not Implemented
WV0076 # 08 Y:1996 08 1996 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,970 $690 Implemented
WV0076 # 09 Y:1996 09 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $1,145 $0 Implemented