Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,257

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0145 # 08 Y:2008 08 2008 CONDENSE OPERATION INTO ONE BUILDING $3,114 $0 Not Implemented
IC0145 # 09 Y:2008 09 2008 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $611 $0 Not Implemented
IA0427 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,287 $11,165 Not Implemented
IA0427 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $1,378 $1,694 Not Implemented
IA0427 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $966 $725 Not Implemented
IA0427 # 04 Y:2008 04 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $738 $65 Not Implemented
IA0427 # 05 Y:2008 05 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,020 $820 Not Implemented
IA0427 # 06 Y:2008 06 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,859 $3,040 Not Implemented
IA0427 # 07 Y:2008 07 2008 COVER OPEN TANKS $1,164 $2,525 Not Implemented
IA0427 # 08 Y:2008 08 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,989 $18,000 Not Implemented
IA0427 # 09 Y:2008 09 2008 ADJUST BURNERS FOR EFFICIENT OPERATION $14,857 $3,120 Not Implemented
IA0427 # 10 Y:2008 10 2008 ISOLATE HOT OR COLD EQUIPMENT $15,047 $1,869 Not Implemented
GT0852 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,327 $3,500 Implemented
GT0852 # 02 Y:2008 02 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,774 $0 Implemented
GT0852 # 03 Y:2008 03 2008 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $9,073 $9,000 Not Implemented
GT0852 # 04 Y:2008 04 2008 RECOVER WASTE HEAT FROM EQUIPMENT $790 $2,775 Not Implemented
GT0852 # 05 Y:2008 05 2008 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $9,500 $15,600 Not Implemented
GT0852 # 06 Y:2008 06 2008 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $22,600 $60,000 Not Implemented
GT0852 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,667 $37,500 Implemented
GT0852 # 08 Y:2008 08 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,037 $64,132 Not Implemented
IC0140 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,573 $4,032 Not Implemented
IC0140 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $540 $1,133 Not Implemented
IC0140 # 03 Y:2008 03 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $12,321 $0 Not Implemented
IC0140 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,900 $1,940 Not Implemented
IC0140 # 05 Y:2008 05 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,785 $2,728 Not Implemented