Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

25

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CL2015 # 01 Y:2020 01 2020 MODIFY STARTUP/SHUTDOWN TIMES $7,855 $550 Not Implemented
CL2015 # 02 Y:2020 02 2020 USE OPTIMUM TEMPERATURE $17,243 $0 Not Implemented
CL2015 # 03 Y:2020 03 2020 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $53 $0 Not Implemented
CL2015 # 04 Y:2020 04 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,229 $4,600 Not Implemented
NC0560 # 03 Y:2016 03 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,460 $200 Implemented
NC0560 # 15 Y:2016 15 2016 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $1,030 $200 Not Implemented
NC0560 # 14 Y:2016 14 2016 DEVELOP A REPAIR/REPLACE POLICY $2,514 $5,865 Implemented
NC0560 # 13 Y:2016 13 2016 TURN OFF EQUIPMENT WHEN NOT IN USE $3,597 $500 Implemented
NC0560 # 12 Y:2016 12 2016 USE PHOTOCELL CONTROLS $194 $250 Implemented
NC0560 # 11 Y:2016 11 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $474 $455 Implemented
NC0560 # 10 Y:2016 10 2016 INSTALL OCCUPANCY SENSORS $519 $521 Implemented
NC0560 # 09 Y:2016 09 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $812 $300 Not Implemented
NC0560 # 08 Y:2016 08 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,436 $6,000 Not Implemented
NC0560 # 07 Y:2016 07 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,287 $100 Not Implemented
NC0560 # 06 Y:2016 06 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,027 $500 Not Implemented
NC0560 # 05 Y:2016 05 2016 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $12,243 $26,000 Implemented
NC0560 # 04 Y:2016 04 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $17,627 $1,000 Implemented
NC0560 # 02 Y:2016 02 2016 RECOVER WASTE HEAT FROM EQUIPMENT $15,200 $4,000 Implemented
NC0560 # 01 Y:2016 01 2016 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $35,613 $105,000 Not Implemented
TN0660 # 01 Y:1999 01 1999 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $56,525 $880 Implemented
TN0660 # 06 Y:1999 06 1999 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $3,300 $8,200 Implemented
TN0660 # 05 Y:1999 05 1999 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $5,360 $1,070 Implemented
TN0660 # 04 Y:1999 04 1999 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $5,450 $0 Not Implemented
TN0660 # 03 Y:1999 03 1999 USE DEMAND CONTROLLER OR LOAD SHEDDER $9,247 $4,700 Implemented
TN0660 # 02 Y:1999 02 1999 $20,100 $50,000 Implemented