Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
432
matching recommendationsSIC | 3562 | Ball And Roller Bearings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0531 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $874 | $1,255 | Not Implemented |
OK0871 # 01 Y:2014 | 01 | 2014 | INSTALL SET-BACK TIMERS | $1,092 | $676 | Implemented |
OK0871 # 02 Y:2014 | 02 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $774 | $280 | Implemented |
OK0871 # 03 Y:2014 | 03 | 2014 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,523 | $5,398 | Not Implemented |
OK0871 # 04 Y:2014 | 04 | 2014 | INSTALL SET-BACK TIMERS | $701 | $2,100 | Implemented |
OK0871 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,148 | $24,197 | Not Implemented |
OK0871 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,142 | $3,353 | Not Implemented |
OK0871 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $507 | $4,399 | Not Implemented |
OK0871 # 08 Y:2014 | 08 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,956 | $4,399 | Implemented |
OK0871 # 09 Y:2014 | 09 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $521 | $689 | Not Implemented |
OK0871 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,242 | $500 | Implemented |
LE0374 # 11 Y:2014 | 11 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $1,698 | Not Implemented |
LE0374 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $291 | $877 | Not Implemented |
LE0374 # 09 Y:2014 | 09 | 2014 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,123 | $2,050 | Not Implemented |
LE0374 # 08 Y:2014 | 08 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $45,444 | $72,000 | Not Implemented |
LE0374 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,426 | $9,048 | Not Implemented |
LE0374 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,789 | $57,000 | Not Implemented |
LE0374 # 05 Y:2014 | 05 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $589 | $166 | Not Implemented |
LE0374 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,587 | $1,000 | Not Implemented |
LE0374 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,422 | $393 | Not Implemented |
LE0374 # 02 Y:2014 | 02 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $1,034 | $48 | Not Implemented |
LE0374 # 01 Y:2014 | 01 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,907 | $48 | Not Implemented |
NC0483 # 01 Y:2013 | 01 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $240,743 | $750,000 | Not Implemented |
NC0483 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,552 | $69,000 | Not Implemented |
NC0483 # 03 Y:2013 | 03 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,715 | $20,000 | Not Implemented |