Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 3564 | Blowers And Fans |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0850 # 03 Y:2022 | 03 | 2022 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,225 | $1,720 | Not Implemented |
AM0850 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,030 | $9,225 | Implemented |
AM0850 # 01 Y:2022 | 01 | 2022 | OPTIMIZE PLANT POWER FACTOR | $10,860 | $17,420 | Implemented |
AM0850 # 04 Y:2022 | 04 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,765 | $70 | Implemented |
AM0850 # 05 Y:2022 | 05 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $910 | $1,000 | Implemented |
AM0850 # 08 Y:2022 | 08 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $285 | $0 | Implemented |
AM0850 # 07 Y:2022 | 07 | 2022 | PAY UTILITY BILLS ON TIME | $389 | $0 | Implemented |
AM0850 # 06 Y:2022 | 06 | 2022 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $810 | $1,363 | Not Implemented |
TA0117 # 04 Y:2006 | 04 | 2006 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $478 | $0 | Implemented |
TA0117 # 05 Y:2006 | 05 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,356 | $0 | Implemented |
TA0117 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,208 | $5,065 | Implemented |
TA0117 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,020 | $7,980 | Implemented |
TA0117 # 06 Y:2006 | 06 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $45,290 | $22,980 | Not Implemented |
TA0117 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,925 | $9 | Implemented |
TA0095 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,370 | $0 | Not Implemented |
TA0095 # 01 Y:2005 | 01 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $17,820 | $1,035 | Not Implemented |
TA0095 # 02 Y:2005 | 02 | 2005 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $9,270 | $2,660 | Not Implemented |
TA0095 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,300 | $530 | Implemented |
TA0095 # 08 Y:2005 | 08 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $430 | $0 | Not Implemented |
TA0095 # 04 Y:2005 | 04 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,440 | $2,000 | Not Implemented |
TA0095 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,615 | $0 | Not Implemented |
TA0095 # 06 Y:2005 | 06 | 2005 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $270 | $0 | Not Implemented |
AM0302 # 11 Y:1997 | 11 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $140 | $70 | Not Implemented |
AM0302 # 10 Y:1997 | 10 | 1997 | CONVERT TO AQUEOUS CLEANING | $150 | $0 | Not Implemented |
AM0302 # 08 Y:1997 | 08 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $210 | $0 | Implemented |