Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 3564 | Blowers And Fans |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0526 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,600 | $810 | Not Implemented |
KU0526 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,050 | $10,000 | Not Implemented |
KU0526 # 05 Y:1999 | 05 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $52,280 | $151,000 | Not Implemented |
KU0526 # 03 Y:1999 | 03 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,000 | $0 | Not Implemented |
KU0526 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $700 | $1,050 | Not Implemented |
UL0228 # 06 Y:1999 | 06 | 1999 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $250,000 | $0 | Not Implemented |
UL0228 # 05 Y:1999 | 05 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $88,740 | $1,560 | Not Implemented |
UL0228 # 04 Y:1999 | 04 | 1999 | USE LESS WASTEFUL PACKAGING | $58,958 | $1,000 | Not Implemented |
UL0228 # 03 Y:1999 | 03 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $9,641 | $10,400 | Not Implemented |
UL0228 # 02 Y:1999 | 02 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $8,550 | $0 | Not Implemented |
UL0228 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,001 | $20 | Implemented |
MS0138 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $187 | $197 | Implemented |
MS0138 # 08 Y:1999 | 08 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $18,055 | $720 | Implemented |
MS0138 # 07 Y:1999 | 07 | 1999 | BURN WASTE OIL FOR HEAT | $1,399 | $2,555 | Not Implemented |
MS0138 # 06 Y:1999 | 06 | 1999 | USE SYNTHETIC LUBRICANT | $4,376 | $825 | Not Implemented |
MS0138 # 05 Y:1999 | 05 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,832 | $3,788 | Implemented |
MS0138 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,462 | $266 | Implemented |
MS0138 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,777 | $1,994 | Implemented |
MS0138 # 02 Y:1999 | 02 | 1999 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $884 | $80 | Implemented |
NC0163 # 07 Y:1999 | 07 | 1999 | TREAT AND REUSE RINSE WATERS | $7,389 | $4,500 | Implemented |
NC0163 # 08 Y:1999 | 08 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $55,000 | $14,000 | Implemented |
NC0163 # 06 Y:1999 | 06 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,068 | $1,000 | Implemented |
NC0163 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,985 | $35,000 | Not Implemented |
NC0163 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,866 | $25 | Implemented |
NC0163 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,614 | $1,600 | Implemented |