Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
64
matching recommendationsSIC | 3566 | Speed Changers, Drives, And Gears |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0070 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,895 | $46,610 | Not Implemented |
IC0070 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,127 | $2,716 | Not Implemented |
IC0070 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $8,874 | $22,864 | Not Implemented |
IC0070 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $51,638 | $160,788 | Not Implemented |
IC0070 # 05 Y:2003 | 05 | 2003 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,377 | $0 | Not Implemented |
IC0070 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $56,367 | $4,200 | Implemented |
IC0070 # 07 Y:2003 | 07 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58,133 | $0 | Implemented |
IC0070 # 08 Y:2003 | 08 | 2003 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $73,846 | $613,200 | Not Implemented |
IC0068 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,566 | $12,133 | Not Implemented |
IC0068 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,412 | $0 | Not Implemented |
IC0068 # 02 Y:2003 | 02 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $3,197 | $855 | Not Implemented |
IC0068 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $717 | $2,397 | Not Implemented |
IC0068 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $701 | $1,279 | Not Implemented |
IC0068 # 06 Y:2003 | 06 | 2003 | UPGRADE OBSOLETE EQUIPMENT | $84 | $179 | Not Implemented |
IC0068 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $919 | $5,605 | Not Implemented |
IC0067 # 09 Y:2003 | 09 | 2003 | REDUCE OR ELIMINATE WASTE | $13,650 | $2,107 | Not Implemented |
IC0067 # 08 Y:2003 | 08 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $13,670 | $0 | Not Implemented |
IC0067 # 07 Y:2003 | 07 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,728 | $19,284 | Not Implemented |
IC0067 # 06 Y:2003 | 06 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,376 | $0 | Implemented |
IC0067 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,441 | $72,201 | n/a |
IC0067 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,779 | $2,600 | Implemented |
IC0067 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $1,742 | $4,527 | Not Implemented |
IC0067 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,567 | $29,205 | Not Implemented |
IC0067 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,485 | $0 | Implemented |
IC0023 # 06 Y:2001 | 06 | 2001 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $11,745 | $14,000 | n/a |