Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
286
matching recommendationsSIC | 3568 | Power Transmission Equipment, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0498 # 07 Y:2020 | 07 | 2020 | USE PHOTOCELL CONTROLS | $380 | $615 | Not Implemented |
SU0498 # 02 Y:2020 | 02 | 2020 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $325 | $60 | Not Implemented |
SU0498 # 05 Y:2020 | 05 | 2020 | DISCONNECT BALLASTS | $81 | $30 | Not Implemented |
SU0498 # 06 Y:2020 | 06 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $323 | $427 | Not Implemented |
LE0486 # 05 Y:2019 | 05 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,256 | $65,000 | Not Implemented |
LE0486 # 03 Y:2019 | 03 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,174 | $1,540 | Implemented |
LE0486 # 06 Y:2019 | 06 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,726 | $7,400 | Not Implemented |
LE0486 # 02 Y:2019 | 02 | 2019 | INSTALL TIMERS AND/OR THERMOSTATS | $8,764 | $720 | Implemented |
LE0486 # 01 Y:2019 | 01 | 2019 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $57,024 | $500 | Not Implemented |
LE0486 # 07 Y:2019 | 07 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,558 | $28,275 | Implemented |
LE0486 # 04 Y:2019 | 04 | 2019 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $15,202 | $21,000 | Not Implemented |
UA0153 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,306 | $65,413 | Not Implemented |
UA0153 # 06 Y:2016 | 06 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,300 | $2,995 | Not Implemented |
UA0153 # 04 Y:2016 | 04 | 2016 | USE PHOTOCELL CONTROLS | $329 | $118 | Implemented |
UA0153 # 01 Y:2016 | 01 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $73,794 | $99,000 | Not Implemented |
UA0153 # 05 Y:2016 | 05 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,753 | $100 | Not Implemented |
UA0153 # 02 Y:2016 | 02 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $25,593 | $4,000 | Implemented |
UA0153 # 08 Y:2016 | 08 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $537 | $0 | Implemented |
UA0153 # 07 Y:2016 | 07 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,568 | $5,780 | Not Implemented |
AM0686 # 09 Y:2015 | 09 | 2015 | PAY UTILITY BILLS ON TIME | $1,789 | $0 | Not Implemented |
AM0686 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,915 | $1,810 | Not Implemented |
AM0686 # 06 Y:2015 | 06 | 2015 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $12,685 | $17,600 | Not Implemented |
AM0686 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $455 | $220 | Not Implemented |
AM0686 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $895 | $5 | Not Implemented |
AM0686 # 02 Y:2015 | 02 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,790 | $0 | Not Implemented |