Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsSIC | 3569 | General Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0534 # 08 Y:1997 | 08 | 1997 | USE OTHER WASTE CONCENTRATION METHODS | $2,932 | $500 | Not Implemented |
UD0534 # 07 Y:1997 | 07 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $35,000 | $75,000 | Implemented |
UD0534 # 06 Y:1997 | 06 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $8,275 | $0 | Not Implemented |
UD0534 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $7,454 | $1,400 | Implemented |
UD0534 # 04 Y:1997 | 04 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $789 | $400 | Not Implemented |
UD0534 # 03 Y:1997 | 03 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,860 | $600 | Not Implemented |
UD0534 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,347 | $29,176 | Implemented |
UD0534 # 01 Y:1997 | 01 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,360 | $6,000 | Not Implemented |
NC0119 # 11 Y:1997 | 11 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,369 | $5,200 | Not Implemented |
NC0119 # 12 Y:1997 | 12 | 1997 | IMPROVE SPACE COMFORT CONDITIONING | $80,000 | $200,000 | Not Implemented |
NC0119 # 01 Y:1997 | 01 | 1997 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,540 | $9,360 | Not Implemented |
NC0119 # 10 Y:1997 | 10 | 1997 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $2,906 | $6,000 | Not Implemented |
NC0119 # 09 Y:1997 | 09 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $8,671 | $26,025 | Not Implemented |
NC0119 # 08 Y:1997 | 08 | 1997 | REDUCE SCRAP PRODUCTION | $13,896 | $15,000 | Implemented |
NC0119 # 07 Y:1997 | 07 | 1997 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $8,808 | $39,078 | Not Implemented |
NC0119 # 06 Y:1997 | 06 | 1997 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,220 | $45,000 | Not Implemented |
NC0119 # 05 Y:1997 | 05 | 1997 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,047 | $43,046 | Not Implemented |
NC0119 # 04 Y:1997 | 04 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,369 | $0 | Not Implemented |
NC0119 # 03 Y:1997 | 03 | 1997 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,719 | $5,750 | Implemented |
NC0119 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $832 | $180 | Implemented |