Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

442

matching recommendations
Reset
SIC 357 Computer And Office Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0399 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $861 $1,632 Not Implemented
AS0399 # 03 Y:2005 03 2005 USE SOLAR HEAT TO HEAT WATER $690 $1,100 Not Implemented
AS0399 # 04 Y:2005 04 2005 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $318 $506 Not Implemented
UF0270 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,259 $10,393 Not Implemented
UF0270 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $394 $518 Not Implemented
UF0270 # 03 Y:2001 03 2001 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $5,283 $50 Not Implemented
UF0270 # 04 Y:2001 04 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,583 $15,092 Not Implemented
UF0270 # 05 Y:2001 05 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,461 $350 Not Implemented
UF0270 # 06 Y:2001 06 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,414 $0 Not Implemented
UF0270 # 07 Y:2001 07 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $532 $1,500 Not Implemented
UF0270 # 08 Y:2001 08 2001 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $4,992 $800 Not Implemented
UF0270 # 09 Y:2001 09 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $852 $600 Not Implemented
UF0258 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,278 $0 Implemented
UF0258 # 02 Y:2000 02 2000 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $833 $0 Implemented
UF0258 # 03 Y:2000 03 2000 INSTALL OCCUPANCY SENSORS $414 $0 Not Implemented
UF0258 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,054 $0 Implemented
UF0258 # 05 Y:2000 05 2000 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS $18,176 $0 Implemented
UF0258 # 06 Y:2000 06 2000 METER WASTE WATER $306 $0 Implemented
UF0258 # 07 Y:2000 07 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $14,400 $0 Implemented
NV0136 # 01 Y:1999 01 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,174 $1,500 Not Implemented
NV0136 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,742 $900 Implemented
NV0136 # 03 Y:1999 03 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $10,471 $15,285 Not Implemented
NV0136 # 04 Y:1999 04 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $274 $0 Implemented
NV0136 # 05 Y:1999 05 1999 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $900 $0 Not Implemented
UM0145 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,720 $300 Implemented