Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73
matching recommendationsSIC | 357 | Computer And Office Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0683 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,540 | $21,440 | Not Implemented |
CO0683 # 02 Y:2014 | 02 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,750 | $13,140 | Not Implemented |
CO0683 # 03 Y:2014 | 03 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,270 | $0 | Not Implemented |
CO0683 # 04 Y:2014 | 04 | 2014 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $2,440 | $6,450 | Not Implemented |
CO0674 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,670 | $310 | Implemented |
CO0674 # 03 Y:2013 | 03 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $3,740 | $0 | Not Implemented |
CO0674 # 04 Y:2013 | 04 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,320 | $500 | Not Implemented |
CO0674 # 02 Y:2013 | 02 | 2013 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $4,510 | $13,600 | Not Implemented |
CO0674 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,830 | $250 | Implemented |
CO0439 # 04 Y:1999 | 04 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,620 | $8,400 | Implemented |
CO0439 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,900 | $2,000 | Implemented |
CO0439 # 02 Y:1999 | 02 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $102,440 | $400,000 | Not Implemented |
CO0439 # 01 Y:1999 | 01 | 1999 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $187,200 | $13,080 | Implemented |
CO0408 # 03 Y:1998 | 03 | 1998 | ADD AREA LIGHTING SWITCHES | $690 | $3,600 | Not Implemented |
CO0408 # 05 Y:1998 | 05 | 1998 | ELIMINATE/REDUCE AN OPERATION | $520 | $80 | Implemented |
CO0408 # 04 Y:1998 | 04 | 1998 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $650 | $0 | Not Implemented |
CO0408 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $2,450 | Not Implemented |
CO0408 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $273 | $482 | Implemented |
CO0340 # 05 Y:1995 | 05 | 1995 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $410 | $1,170 | Not Implemented |
CO0340 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $420 | $300 | Not Implemented |
CO0340 # 07 Y:1995 | 07 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $290 | $130 | Implemented |
CO0340 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,040 | $1,990 | Implemented |
CO0340 # 02 Y:1995 | 02 | 1995 | AIR CONDITION ONLY SPACE NECESSARY | $3,580 | $400 | Implemented |
CO0340 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,350 | $3,820 | Not Implemented |
CO0340 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,090 | $3,670 | Implemented |