Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,655

matching recommendations
Reset
SIC 358 Refrigeration And Service Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0124 # 03 Y:2006 03 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,649 $1,500 Not Implemented
IC0124 # 04 Y:2006 04 2006 INSTALL TIMERS AND/OR THERMOSTATS $6,565 $0 Not Implemented
IC0124 # 05 Y:2006 05 2006 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $44,224 $56,250 Not Implemented
IC0124 # 06 Y:2006 06 2006 REPLACE BOILER $4,755 $27,175 Not Implemented
IC0124 # 07 Y:2006 07 2006 TURN OFF EQUIPMENT WHEN NOT IN USE $1,031 $0 Not Implemented
UM0314 # 01 Y:2006 01 2006 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $62,424 $69,750 Not Implemented
UM0314 # 02 Y:2006 02 2006 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS $30,865 $25,000 Not Implemented
UM0314 # 03 Y:2006 03 2006 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $12,963 $2,480 Implemented
UM0314 # 04 Y:2006 04 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $12,296 $7,000 Not Implemented
UM0314 # 05 Y:2006 05 2006 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $9,136 $3,084 Not Implemented
UM0314 # 06 Y:2006 06 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,473 $400 Implemented
UM0314 # 07 Y:2006 07 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,953 $3,286 Not Implemented
UM0314 # 08 Y:2006 08 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $596 $660 Not Implemented
UM0314 # 09 Y:2006 09 2006 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $133 $175 Not Implemented
SU0241 # 01 Y:2006 01 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,985 $0 Not Implemented
SU0241 # 02 Y:2006 02 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $19 $0 Implemented
SU0241 # 03 Y:2006 03 2006 CONVERT TO ELECTROSTATIC POWDER COATING $15,419 $4,500 Not Implemented
SU0241 # 04 Y:2006 04 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $765 $201 Implemented
SU0241 # 05 Y:2006 05 2006 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $5,054 $2,928 Implemented
SU0241 # 06 Y:2006 06 2006 INSTALL OCCUPANCY SENSORS $290 $239 Not Implemented
SU0241 # 07 Y:2006 07 2006 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $602 $712 Not Implemented
SU0241 # 08 Y:2006 08 2006 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $10,784 $19,571 Not Implemented
SU0241 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,800 $24,622 Implemented
NC0333 # 01 Y:2006 01 2006 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $25,187 $9,000 Not Implemented
NC0333 # 02 Y:2006 02 2006 RECOVER WASTE HEAT FROM EQUIPMENT $12,607 $4,635 Not Implemented