Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,624

matching recommendations
Reset
SIC 358 Refrigeration And Service Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0113 # 02 Y:1984 02 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $15,633 $4,906 Implemented
UD0113 # 03 Y:1984 03 1984 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,847 $0 Implemented
UD0113 # 04 Y:1984 04 1984 INSULATE BARE EQUIPMENT $608 $200 Implemented
UD0113 # 05 Y:1984 05 1984 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $13,999 $30,000 Implemented
KU0105 # 01 Y:1983 01 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,036 $200 Not Implemented
KU0105 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,910 $41,000 Not Implemented
KU0105 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $10,333 $3,000 Not Implemented
KU0105 # 04 Y:1983 04 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,827 $2,400 Implemented
KU0105 # 05 Y:1983 05 1983 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,951 $0 Not Implemented
KU0105 # 06 Y:1983 06 1983 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $28,238 $35,000 Not Implemented
KU0105 # 07 Y:1983 07 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $529 $1,000 Not Implemented
GT0184 # 04 Y:1983 04 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,100 $6,000 Implemented
GT0184 # 05 Y:1983 05 1983 INSULATE BARE EQUIPMENT $2,600 $4,580 Implemented
GT0184 # 01 Y:1983 01 1983 KEEP BOILER TUBES CLEAN $1,560 $1,500 Implemented
GT0184 # 02 Y:1983 02 1983 INSTALL / REPAIR INSULATION ON STEAM LINES $2,600 $4,530 Implemented
GT0184 # 03 Y:1983 03 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,470 $2,400 Implemented
KU0091 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,478 $912 Not Implemented
KU0091 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $1,331 $400 Not Implemented
KU0091 # 03 Y:1983 03 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $461 $522 Not Implemented
KU0091 # 04 Y:1983 04 1983 INSTALL AUTOMATIC STACK DAMPER $300 $300 Not Implemented
KU0091 # 05 Y:1983 05 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $223 $90 Not Implemented
TN0171 # 01 Y:1983 01 1983 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $23,000 $13,000 Not Implemented
TN0171 # 02 Y:1983 02 1983 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $5,000 $0 Not Implemented
TN0171 # 03 Y:1983 03 1983 INSTALL / REPAIR INSULATION ON STEAM LINES $3,800 $400 Not Implemented
UD0084 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,160 $1,527 Not Implemented