Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

48

matching recommendations
Reset
SIC 3585 Refrigeration And Heating Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0271 # 05 Y:2000 05 2000 KEEP EQUIPMENT CLEAN $3,601 $232 Implemented
AS0271 # 04 Y:2000 04 2000 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $10,502 $30,380 Not Implemented
AS0271 # 03 Y:2000 03 2000 INSTALL TIMERS AND/OR THERMOSTATS $591 $600 Not Implemented
AS0271 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $708 $607 Implemented
AS0271 # 01 Y:2000 01 2000 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $1,637 $1,266 Not Implemented
AS0081 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $126 $612 Implemented
AS0081 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $230 $323 Implemented
AS0081 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $249 $0 Implemented
AS0081 # 04 Y:1993 04 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $479 $1,179 Not Implemented
AS0081 # 05 Y:1993 05 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $991 $0 Not Implemented
AS0081 # 06 Y:1993 06 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,092 $570 Implemented
AS0081 # 07 Y:1993 07 1993 USE SYNTHETIC LUBRICANT $1,031 $0 Implemented
AS0081 # 08 Y:1993 08 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,199 $4,250 Implemented
AS0015 # 01 Y:1990 01 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,956 $1,000 Implemented
AS0015 # 10 Y:1990 10 1990 RECOVER WASTE HEAT FROM EQUIPMENT $2,463 $1,760 Not Implemented
AS0015 # 09 Y:1990 09 1990 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,119 $2,775 Not Implemented
AS0015 # 08 Y:1990 08 1990 INSTALL SET-BACK TIMERS $1,698 $450 Implemented
AS0015 # 07 Y:1990 07 1990 KEEP LAMPS AND REFLECTORS CLEAN $15,919 $20,225 Implemented
AS0015 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,214 $520 Not Implemented
AS0015 # 05 Y:1990 05 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $20,041 $0 Implemented
AS0015 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,240 $808 Not Implemented
AS0015 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,814 $0 Implemented
AS0015 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,924 $4,119 Implemented