Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 3585 | Refrigeration And Heating Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0789 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,800 | $198,000 | Implemented |
GT0789 # 08 Y:2004 | 08 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $964 | $2,900 | Not Implemented |
GT0789 # 07 Y:2004 | 07 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,570 | $6,000 | Implemented |
GT0789 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,160 | $2,400 | Implemented |
GT0789 # 05 Y:2004 | 05 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $21,400 | $9,700 | Implemented |
GT0789 # 04 Y:2004 | 04 | 2004 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,717 | $300 | Not Implemented |
GT0789 # 03 Y:2004 | 03 | 2004 | DISCONNECT BALLASTS | $639 | $645 | Implemented |
GT0789 # 02 Y:2004 | 02 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $3,090 | $1,824 | Implemented |
GT0789 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $63,136 | $0 | Implemented |
OK0692 # 11 Y:2004 | 11 | 2004 | INSTALL OCCUPANCY SENSORS | $1,911 | $1,690 | Not Implemented |
OK0692 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,239 | $2,275 | Implemented |
OK0692 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,206 | $10,250 | Not Implemented |
OK0692 # 03 Y:2004 | 03 | 2004 | USE COMPRESSOR AIR FILTERS | $5,114 | $7,875 | Not Implemented |
OK0692 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,221 | $8,625 | Implemented |
OK0692 # 05 Y:2004 | 05 | 2004 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,389 | $6,675 | Not Implemented |
OK0692 # 06 Y:2004 | 06 | 2004 | INSTALL SET-BACK TIMERS | $81,447 | $10,000 | Implemented |
OK0692 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $8,800 | $0 | Implemented |
OK0692 # 08 Y:2004 | 08 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $17,464 | $5,050 | Not Implemented |
OK0692 # 09 Y:2004 | 09 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $663,000 | $130,000 | Not Implemented |
OK0692 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,577 | $11,882 | Implemented |
OK0691 # 01 Y:2004 | 01 | 2004 | INSTALL EQUIPMENT TO MOVE PRODUCT | $90,154 | $5,782 | Not Implemented |
OK0691 # 02 Y:2004 | 02 | 2004 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $270,439 | $2,825 | Implemented |
OK0691 # 03 Y:2004 | 03 | 2004 | INSTALL SET-BACK TIMERS | $6,531 | $3,832 | Implemented |
OK0691 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,036 | $559 | Implemented |
OK0691 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $265 | $0 | Implemented |