Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
429
matching recommendationsSIC | 3589 | Service Industry Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0336 # 03 Y:1995 | 03 | 1995 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $1,510 | $340 | Not Implemented |
CO0336 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $920 | $980 | Implemented |
CO0336 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $790 | $130 | Implemented |
CO0336 # 06 Y:1995 | 06 | 1995 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $380 | $500 | Not Implemented |
CO0336 # 07 Y:1995 | 07 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $360 | $690 | Implemented |
CO0336 # 08 Y:1995 | 08 | 1995 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $300 | $0 | Not Implemented |
UD0457 # 01 Y:1995 | 01 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,868 | $200 | Implemented |
UD0457 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,446 | $0 | Implemented |
UD0457 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $612 | $2,000 | Not Implemented |
UD0457 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $687 | $1,625 | Implemented |
SD0100 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $206 | $380 | Not Implemented |
SD0100 # 02 Y:1994 | 02 | 1994 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,434 | $2,000 | Implemented |
SD0100 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $93 | $140 | Implemented |
SD0100 # 04 Y:1994 | 04 | 1994 | INSULATE BARE EQUIPMENT | $405 | $43 | Implemented |
SD0100 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,131 | $7,029 | Not Implemented |
SD0100 # 06 Y:1994 | 06 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,373 | $3,675 | Implemented |
SD0100 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $1,542 | $607 | Not Implemented |
SD0100 # 08 Y:1994 | 08 | 1994 | USE PHOTOCELL CONTROLS | $2,123 | $1,278 | Not Implemented |
SD0100 # 09 Y:1994 | 09 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $89 | $50 | Implemented |
NC0033 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $368 | $300 | Not Implemented |
NC0033 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $132 | $420 | Not Implemented |
NC0033 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $645 | $1,330 | Not Implemented |
NC0033 # 04 Y:1994 | 04 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $241 | $530 | Not Implemented |
NC0033 # 05 Y:1994 | 05 | 1994 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $120 | $250 | Not Implemented |
NC0033 # 06 Y:1994 | 06 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,143 | $9,600 | Not Implemented |