Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

221

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0353 # 05 Y:2008 05 2008 RECOVER WASTE HEAT FROM EQUIPMENT $437 $1,000 Not Implemented
BD0353 # 06 Y:2008 06 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,431 $200 Not Implemented
BD0353 # 07 Y:2008 07 2008 USE RADIANT HEATER FOR SPOT HEATING $4,341 $5,300 Not Implemented
BD0353 # 08 Y:2008 08 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,315 $3,150 Not Implemented
BD0353 # 09 Y:2008 09 2008 USE EVAPORATION TO CONCENTRATE MATERIAL $6,150 $7,400 Not Implemented
BD0347 # 08 Y:2008 08 2008 USE EVAPORATION TO CONCENTRATE MATERIAL $5,997 $7,996 Not Implemented
BD0347 # 07 Y:2008 07 2008 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,228 $257 Not Implemented
BD0347 # 06 Y:2008 06 2008 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $898 $2,101 Not Implemented
BD0347 # 05 Y:2008 05 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $41,601 $43,021 Not Implemented
BD0347 # 04 Y:2008 04 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,195 $501 Not Implemented
BD0347 # 03 Y:2008 03 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,032 $2 Not Implemented
BD0347 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $4,457 $5,400 Implemented
BD0347 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $51,977 $120 Implemented
BD0270 # 06 Y:2004 06 2004 RECOVER WASTE HEAT FROM EQUIPMENT $2,453 $3,500 Not Implemented
BD0270 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,872 $0 Implemented
BD0270 # 02 Y:2004 02 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $13,615 $24,000 Implemented
BD0270 # 03 Y:2004 03 2004 USE RADIANT HEATER FOR SPOT HEATING $11,491 $18,616 Not Implemented
BD0270 # 04 Y:2004 04 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $11,396 $480 Not Implemented
BD0270 # 05 Y:2004 05 2004 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $4,757 $1,000 Not Implemented
BD0270 # 07 Y:2004 07 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,382 $750 Implemented
BD0270 # 08 Y:2004 08 2004 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $2,173 $75 Implemented
BD0270 # 09 Y:2004 09 2004 USE PHOTOCELL CONTROLS $1,040 $320 Implemented
BD0270 # 10 Y:2004 10 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $353 $168 Implemented
BD0270 # 12 Y:2004 12 2004 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $0 $3,000 Not Implemented
BD0270 # 11 Y:2004 11 2004 MINIMIZE WATER USAGE $3,135 $1,320 Not Implemented