Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,249

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0131 # 02 Y:2002 02 2002 OPTIMIZE PLANT POWER FACTOR $3,864 $9,240 Not Implemented
LL0131 # 03 Y:2002 03 2002 INSTALL SET-BACK TIMERS $909 $1,097 Implemented
LL0131 # 04 Y:2002 04 2002 PAY BILLS ON TIME TO AVOID LATE FEES $600 $0 Not Implemented
LL0131 # 05 Y:2002 05 2002 INSTALL OCCUPANCY SENSORS $213 $81 Not Implemented
LL0131 # 06 Y:2002 06 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $159 $0 Not Implemented
WV0234 # 01 Y:2002 01 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,079 $800 Implemented
WV0234 # 02 Y:2002 02 2002 UTILIZE A LESS EXPENSIVE COOLING METHOD $9,910 $4,200 Implemented
WV0234 # 03 Y:2002 03 2002 USE OPTIMUM THICKNESS INSULATION $6,520 $2,125 Not Implemented
WV0234 # 04 Y:2002 04 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $3,825 $660 Implemented
WV0234 # 05 Y:2002 05 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,903 $4,076 Not Implemented
WV0234 # 06 Y:2002 06 2002 RECOVER WASTE HEAT FROM EQUIPMENT $1,512 $2,020 Not Implemented
WV0234 # 07 Y:2002 07 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,201 $22 Implemented
WV0234 # 08 Y:2002 08 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $8,732 $1,650 Implemented
WV0234 # 09 Y:2002 09 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $712 $758 Not Implemented
WV0234 # 10 Y:2002 10 2002 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,260 $1,342 Not Implemented
WV0234 # 11 Y:2002 11 2002 CLEAR AND RENT EXISTING SPACE $7,300 $1,160 Implemented
WV0234 # 12 Y:2002 12 2002 CLEAR AND RENT EXISTING SPACE $50,000 $1,500 Not Implemented
BD0205 # 01 Y:2002 01 2002 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $133,965 $75,270 Not Implemented
BD0205 # 02 Y:2002 02 2002 USE RADIANT HEATER FOR SPOT HEATING $25,105 $60,000 Not Implemented
BD0205 # 03 Y:2002 03 2002 INSTALL AUTOMATIC STACK DAMPER $4,550 $5,000 Not Implemented
BD0205 # 04 Y:2002 04 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,089 $4,800 Implemented
BD0205 # 05 Y:2002 05 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,003 $1,000 Implemented
BD0205 # 06 Y:2002 06 2002 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,411 $1,500 Not Implemented
BD0205 # 07 Y:2002 07 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,387 $300 Implemented
BD0205 # 08 Y:2002 08 2002 INSTALL OCCUPANCY SENSORS $1,324 $1,425 Not Implemented