Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 3592 | Carburetors, Pistons, Rings, Valves |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0291 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $20,293 | $9,000 | Implemented |
UM0291 # 02 Y:2005 | 02 | 2005 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $18,138 | $19,073 | Not Implemented |
UM0291 # 03 Y:2005 | 03 | 2005 | COVER OPEN TANKS | $4,518 | $2,366 | Implemented |
UM0291 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,427 | $1,900 | Implemented |
UM0291 # 05 Y:2005 | 05 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,841 | $1,490 | Not Implemented |
UM0291 # 06 Y:2005 | 06 | 2005 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $2,309 | $39,000 | Not Implemented |
UM0291 # 07 Y:2005 | 07 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,325 | $1,265 | Implemented |
UM0291 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $396 | $150 | Not Implemented |
GT0810 # 01 Y:2005 | 01 | 2005 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $30,000 | $0 | Not Implemented |
GT0810 # 02 Y:2005 | 02 | 2005 | RECOVER AND REUSE WASTE MATERIAL | $20,000 | $0 | Not Implemented |
GT0810 # 03 Y:2005 | 03 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $26,359 | $9,400 | Not Implemented |
GT0810 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,228 | $6,378 | Implemented |
GT0810 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,562 | $7,239 | Not Implemented |
GT0810 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $7,399 | $7,301 | Not Implemented |
GT0810 # 07 Y:2005 | 07 | 2005 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,167 | $14,160 | Not Implemented |
GT0810 # 08 Y:2005 | 08 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $25,152 | $62,500 | Not Implemented |