Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsSIC | 3599 | Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0447 # 01 Y:2024 | 01 | 2024 | UPGRADE OBSOLETE EQUIPMENT | $636,028 | $600,000 | n/a |
MI0447 # 02 Y:2024 | 02 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,522 | $700 | n/a |
MI0447 # 03 Y:2024 | 03 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,651 | $7,497 | n/a |
MI0447 # 04 Y:2024 | 04 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,899 | $1,980 | n/a |
MI0447 # 05 Y:2024 | 05 | 2024 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,840 | $3,750 | n/a |
MI0447 # 06 Y:2024 | 06 | 2024 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $792 | $320 | n/a |
UF0588 # 05 Y:2022 | 05 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $14,162 | $12,350 | Implemented |
UF0588 # 07 Y:2022 | 07 | 2022 | IMPROVE SPACE COMFORT CONDITIONING | $9,728 | $4,480 | Implemented |
UF0588 # 02 Y:2022 | 02 | 2022 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $84,856 | $35,131 | Not Implemented |
UF0588 # 03 Y:2022 | 03 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $22,121 | $756 | Implemented |
UF0588 # 01 Y:2022 | 01 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $91,215 | $297,040 | Implemented |
UF0588 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,751 | $17,178 | Implemented |
UF0588 # 06 Y:2022 | 06 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,352 | $0 | Implemented |
UF0382 # 11 Y:2006 | 11 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,029 | $3,200 | Not Implemented |
UF0382 # 10 Y:2006 | 10 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,973 | $0 | Not Implemented |
UF0382 # 09 Y:2006 | 09 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $393 | $0 | Not Implemented |
UF0382 # 08 Y:2006 | 08 | 2006 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $5,305 | $1,000 | Not Implemented |
UF0382 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $1,876 | $571 | Not Implemented |
UF0382 # 06 Y:2006 | 06 | 2006 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $21,646 | $1,350 | Not Implemented |
UF0382 # 05 Y:2006 | 05 | 2006 | ADD AREA LIGHTING SWITCHES | $515 | $2,079 | Not Implemented |
UF0382 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $1,971 | $1,275 | Not Implemented |
UF0382 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,902 | $900 | Not Implemented |
UF0382 # 01 Y:2006 | 01 | 2006 | USE PHOTOCELL CONTROLS | $4,721 | $2,760 | Not Implemented |
UF0382 # 12 Y:2006 | 12 | 2006 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,821 | $0 | Not Implemented |
UF0382 # 14 Y:2006 | 14 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,240 | $8,000 | Not Implemented |