IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

502

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0017 # 06 Y:1995 06 1995 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $809 $475 Not Implemented
WI0214 # 01 Y:1994 01 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $30,762 $31,200 Not Implemented
WI0214 # 02 Y:1994 02 1994 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $10,026 $15,000 Not Implemented
WI0214 # 03 Y:1994 03 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $9,933 $600 Implemented
WI0214 # 04 Y:1994 04 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,450 $350 Implemented
WI0214 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,054 $2,036 Implemented
WI0214 # 06 Y:1994 06 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $323 $0 Not Implemented
WI0214 # 07 Y:1994 07 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,682 $500 Implemented
WI0214 # 08 Y:1994 08 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,097 $1,600 Not Implemented
WI0214 # 09 Y:1994 09 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,642 $640 Implemented
WI0214 # 10 Y:1994 10 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $384 $700 Not Implemented
WI0214 # 11 Y:1994 11 1994 ELIMINATE/REDUCE AN OPERATION $7,500 $0 Not Implemented
WI0214 # 12 Y:1994 12 1994 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $2,650 $2,500 Not Implemented
WI0210 # 01 Y:1994 01 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,868 $1,400 Implemented
WI0210 # 02 Y:1994 02 1994 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $5,575 $500 Not Implemented
WI0210 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,328 $5,154 Not Implemented
WI0210 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $625 $375 Not Implemented
WI0210 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,471 $2,200 Implemented
WI0210 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,288 $1,920 Implemented
WI0210 # 07 Y:1994 07 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $551 $500 Implemented
WI0210 # 08 Y:1994 08 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $112 $0 Not Implemented
WI0194 # 01 Y:1993 01 1993 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $22,197 $48,000 Not Implemented
WI0194 # 02 Y:1993 02 1993 INSULATE BARE EQUIPMENT $11,890 $147 Not Implemented
WI0194 # 03 Y:1993 03 1993 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $10,533 $36,000 Not Implemented
WI0194 # 04 Y:1993 04 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,065 $2,458 Not Implemented