IAC logo
IAC Assessment: WI0214
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0214
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1994
Principal Product Reflectors for lighting fixtures (indoor and outdoor)
NAICS n/a
SIC 3648 - Lighting Equipment, Nec
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 100,000
Annual Production 73,500,000 Pieces
Production Hrs. Annual 6,000
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $396,395 5,690,504 kWh $0.07
Natural Gas $191,821 56,567 MMBtu $3.39
TOTAL ENERGY COSTS $588,216
RECOMMENDED SAVINGS* $71,503 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $18,761
#|Description Savings
Cost
Status Electricity Usage Natural Gas Solid Waste (non-haz) Electricity Usage Natural Gas Solid Waste (non-haz)
$ kWh $ MMBtu $ lb
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$30,762
Cost:
$31,200
$30,762 - - - - - $30,762
-
kWh
-
-
MMBtu
-
-
lb
02: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$10,026
Cost:
$15,000
$10,026 143,904 - - - - $10,026
143,904
kWh
-
-
MMBtu
-
-
lb
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$9,933
Cost:
$600
- - $9,933 2,930 - - -
-
kWh
$9,933
2,930
MMBtu
-
-
lb
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$3,450
Cost:
$350
- - $3,450 1,018 - - -
-
kWh
$3,450
1,018
MMBtu
-
-
lb
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,054
Cost:
$2,036
$2,054 29,601 - - - - $2,054
29,601
kWh
-
-
MMBtu
-
-
lb
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$323
Cost:
-
$323 4,689 - - - - $323
4,689
kWh
-
-
MMBtu
-
-
lb
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,682
Cost:
$500
- - $1,682 496 - - -
-
kWh
$1,682
496
MMBtu
-
-
lb
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,097
Cost:
$1,600
- - $1,097 324 - - -
-
kWh
$1,097
324
MMBtu
-
-
lb
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,642
Cost:
$640
$1,642 23,447 - - - - $1,642
23,447
kWh
-
-
MMBtu
-
-
lb
10: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$384
Cost:
$700
$384 5,569 - - - - $384
5,569
kWh
-
-
MMBtu
-
-
lb
11: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$7,500
Cost:
-
- - - - $7,500 24,500 -
-
kWh
-
-
MMBtu
$7,500
24,500
lb
12: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$2,650
Cost:
$2,500
- - - - $2,650 10,500 -
-
kWh
-
-
MMBtu
$2,650
10,500
lb
TOTAL RECOMMENDED Savings:
$71,503
Cost:
$55,126
$45,191 207,210 $16,162 4,768 $10,150 35,000 $45,191
207,210
kWh
$16,162
4,768
MMBtu
$10,150
35,000
lb
TOTAL IMPLEMENTED Savings:
$18,761
Cost:
$4,126
$3,696 53,048 $15,065 4,444 - - $3,696
53,048
kWh
$15,065
4,444
MMBtu
-
-
lb
Savings
Cost
$ kWh $ MMBtu $ lb
Electricity Usage Natural Gas Solid Waste (non-haz) Electricity Usage Natural Gas Solid Waste (non-haz)