IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

753

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0152 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,249 $3,880 Implemented
SF0083 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,635 $28,440 Implemented
SF0083 # 02 Y:1996 02 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $668 $835 Implemented
SF0083 # 03 Y:1996 03 1996 USE SYNTHETIC LUBRICANT $239 $550 Not Implemented
SF0083 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $368 $595 Implemented
SF0083 # 05 Y:1996 05 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $2,222 $3,410 Implemented
SF0083 # 06 Y:1996 06 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,228 $0 Implemented
SF0083 # 07 Y:1996 07 1996 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $3,656 $3,995 Not Implemented
SD0134 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,991 $3,350 Not Implemented
SD0134 # 02 Y:1996 02 1996 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,747 $2,500 Not Implemented
SD0134 # 03 Y:1996 03 1996 COVER OPEN TANKS $679 $161 Not Implemented
SD0134 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,979 $1,860 Not Implemented
SD0134 # 05 Y:1996 05 1996 INSTALL SPECTRAL REFLECTORS / DELAMP $3,101 $5,520 Not Implemented
SD0134 # 06 Y:1996 06 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,336 $1,100 Not Implemented
SD0134 # 07 Y:1996 07 1996 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $878 $100 Not Implemented
SD0134 # 08 Y:1996 08 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $231 $500 Not Implemented
NV0038 # 01 Y:1995 01 1995 INSTALL SKYLIGHTS $1,238 $7,568 Not Implemented
NV0038 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,751 $530 Implemented
NV0038 # 03 Y:1995 03 1995 INSTALL OCCUPANCY SENSORS $557 $491 Not Implemented
NV0038 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $356 $46 Implemented
NV0038 # 05 Y:1995 05 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $191 $84 Implemented
NV0038 # 06 Y:1995 06 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $260 $0 Implemented
NV0038 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $885 $189 Not Implemented
SF0066 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,169 $722 Implemented
SF0066 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,319 $41,870 Not Implemented