Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,551
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0012 # 06 Y:1984 | 06 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $16,597 | $4,000 | Implemented |
CO0012 # 07 Y:1984 | 07 | 1984 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $1,984 | $1,160 | Implemented |
CO0012 # 08 Y:1984 | 08 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $241 | $17 | Implemented |
TN0218 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $8,908 | $15,000 | Not Implemented |
TN0218 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,382 | $0 | Not Implemented |
TN0218 # 03 Y:1984 | 03 | 1984 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $4,352 | $3,700 | Implemented |
TN0218 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,746 | $180 | Not Implemented |
TN0218 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,078 | $4,350 | Not Implemented |
TN0218 # 06 Y:1984 | 06 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $758 | $0 | Not Implemented |
TN0218 # 07 Y:1984 | 07 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $677 | $90 | Implemented |
OK0147 # 01 Y:1984 | 01 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,160 | $900 | Implemented |
OK0147 # 02 Y:1984 | 02 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $509 | $131 | Implemented |
OK0147 # 03 Y:1984 | 03 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,650 | $6,252 | Implemented |
OK0147 # 04 Y:1984 | 04 | 1984 | HEAT WATER WITH EXHAUST HEAT | $7,174 | $6,955 | Not Implemented |
OK0147 # 05 Y:1984 | 05 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $6,120 | $1,236 | Implemented |
OK0147 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $566 | $333 | Implemented |
OK0147 # 07 Y:1984 | 07 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,671 | $1,647 | Implemented |
OK0147 # 08 Y:1984 | 08 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,036 | $720 | Implemented |
OK0147 # 09 Y:1984 | 09 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $492 | $291 | Implemented |
OK0147 # 10 Y:1984 | 10 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,362 | $1,090 | Implemented |
UD0137 # 01 Y:1984 | 01 | 1984 | INSULATE BARE EQUIPMENT | $6,700 | $3,000 | Implemented |
UD0137 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $809 | $1,894 | Not Implemented |
TN0216 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,564 | $4,000 | Not Implemented |
TN0216 # 02 Y:1984 | 02 | 1984 | INSTALL SET-BACK TIMERS | $8,300 | $0 | Implemented |
TN0216 # 03 Y:1984 | 03 | 1984 | COVER OPEN TANKS | $1,096 | $75 | Not Implemented |