Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
249
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0783 # 08 Y:2004 | 08 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,875 | $655 | Implemented |
GT0783 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,242 | $20,982 | Implemented |
GT0783 # 06 Y:2004 | 06 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $4,190 | $1,020 | Implemented |
GT0783 # 05 Y:2004 | 05 | 2004 | METER WASTE WATER | $33,200 | $2,000 | Implemented |
GT0783 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $35,410 | $0 | Implemented |
GT0783 # 03 Y:2004 | 03 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $28,110 | $3,700 | Not Implemented |
GT0783 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,870 | $1,250 | Implemented |
GT0783 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,670 | $3,000 | Not Implemented |
GT0711 # 08 Y:2001 | 08 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $510 | $225 | Not Implemented |
GT0711 # 07 Y:2001 | 07 | 2001 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $140 | $800 | Not Implemented |
GT0711 # 06 Y:2001 | 06 | 2001 | USE SYNTHETIC LUBRICANT | $75 | $0 | Not Implemented |
GT0711 # 05 Y:2001 | 05 | 2001 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $15 | $0 | Implemented |
GT0711 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $310 | Not Implemented |
GT0711 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $845 | $1,450 | Implemented |
GT0711 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,025 | $3,725 | Not Implemented |
GT0711 # 01 Y:2001 | 01 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $6,495 | $2,000 | Not Implemented |
GT0688 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $280 | $800 | Implemented |
GT0688 # 01 Y:2000 | 01 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,444 | $2,240 | Implemented |
GT0688 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,360 | $15,907 | Not Implemented |
GT0688 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,190 | $12,285 | Not Implemented |
GT0688 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,760 | $1,050 | Not Implemented |
GT0688 # 07 Y:2000 | 07 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,920 | $450 | Not Implemented |
GT0688 # 06 Y:2000 | 06 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $17,022 | $53,400 | Implemented |
GT0688 # 08 Y:2000 | 08 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,435 | $4,950 | Not Implemented |
GT0663 # 05 Y:1999 | 05 | 1999 | COMBINE UTILITY METERS | $375 | $0 | Not Implemented |