Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

478

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0294 # 12 Y:2016 12 2016 INSTALL OCCUPANCY SENSORS $1,209 $1,237 Not Implemented
MI0294 # 11 Y:2016 11 2016 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,797 $40 Implemented
MI0294 # 10 Y:2016 10 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,176 $7,505 Not Implemented
MI0294 # 09 Y:2016 09 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,218 $12,637 Not Implemented
MI0294 # 08 Y:2016 08 2016 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,830 $40 Implemented
MI0294 # 07 Y:2016 07 2016 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $4,081 $4,200 Implemented
MI0294 # 06 Y:2016 06 2016 CONDENSE OPERATION INTO ONE BUILDING $5,648 $1,360 Not Implemented
MI0294 # 05 Y:2016 05 2016 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $5,921 $1,441 Implemented
MI0294 # 04 Y:2016 04 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,388 $1,660 Implemented
MI0294 # 03 Y:2016 03 2016 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $8,706 $5,161 Not Implemented
MI0294 # 02 Y:2016 02 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $42,734 $29,594 Implemented
MI0294 # 01 Y:2016 01 2016 LOWER CEILING TO REDUCE CONDITIONED SPACE $48,743 $88,928 Not Implemented
MI0283 # 09 Y:2015 09 2015 INSTALL OCCUPANCY SENSORS $684 $177 Not Implemented
MI0283 # 08 Y:2015 08 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $688 $639 Implemented
MI0283 # 07 Y:2015 07 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $942 $40 Not Implemented
MI0283 # 06 Y:2015 06 2015 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,494 $1,400 Not Implemented
MI0283 # 05 Y:2015 05 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,483 $9,820 Implemented
MI0283 # 04 Y:2015 04 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,361 $1,660 Implemented
MI0283 # 03 Y:2015 03 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $20,030 $160 Implemented
MI0283 # 02 Y:2015 02 2015 LOWER CEILING TO REDUCE CONDITIONED SPACE $54,079 $166,590 Not Implemented
MI0283 # 01 Y:2015 01 2015 UTILIZE A LESS EXPENSIVE COOLING METHOD $75,489 $140,000 Not Implemented
MI0245 # 13 Y:2013 13 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $684 $2,000 Not Implemented
MI0245 # 12 Y:2013 12 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $1,214 $1,694 Implemented
MI0245 # 11 Y:2013 11 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,631 $3,190 Implemented
MI0245 # 10 Y:2013 10 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,980 $440 Not Implemented