Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
181
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0243 # 08 Y:1996 | 08 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $855 | $1,120 | Not Implemented |
ND0243 # 09 Y:1996 | 09 | 1996 | OPTIMIZE PLANT POWER FACTOR | $265 | $192 | Implemented |
ND0243 # 10 Y:1996 | 10 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $518 | $250 | Not Implemented |
ND0243 # 11 Y:1996 | 11 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,180 | $800 | Implemented |
ND0243 # 12 Y:1996 | 12 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $496 | $700 | Not Implemented |
ND0243 # 13 Y:1996 | 13 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,520 | $30,000 | Not Implemented |
ND0241 # 01 Y:1996 | 01 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $431 | $488 | Implemented |
ND0241 # 02 Y:1996 | 02 | 1996 | INSTALL STORM WINDOWS AND DOORS | $9,732 | $23,800 | Not Implemented |
ND0241 # 03 Y:1996 | 03 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,310 | $775 | Implemented |
ND0241 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $91 | $90 | Implemented |
ND0241 # 05 Y:1996 | 05 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $178 | $800 | Not Implemented |
ND0241 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $387 | $900 | Not Implemented |
ND0241 # 07 Y:1996 | 07 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,513 | $0 | Not Implemented |
ND0241 # 08 Y:1996 | 08 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,019 | $970 | Implemented |
ND0241 # 09 Y:1996 | 09 | 1996 | INSULATE FEEDWATER TANK | $609 | $528 | Not Implemented |
ND0241 # 10 Y:1996 | 10 | 1996 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $152 | $72 | Not Implemented |
ND0241 # 11 Y:1996 | 11 | 1996 | RECOVER AND REUSE COOLING WATER | $1,718 | $6,000 | Not Implemented |
ND0241 # 12 Y:1996 | 12 | 1996 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $3,511 | $5,900 | Not Implemented |
UD0323 # 01 Y:1990 | 01 | 1990 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $2,239 | $0 | Not Implemented |
UD0323 # 02 Y:1990 | 02 | 1990 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,073 | $300 | Not Implemented |
UD0323 # 03 Y:1990 | 03 | 1990 | RECOVER AND REUSE COOLING WATER | $1,984 | $300 | Not Implemented |
UD0323 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,470 | $3,000 | Not Implemented |
UD0323 # 05 Y:1990 | 05 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,821 | $23,000 | Not Implemented |
UD0323 # 06 Y:1990 | 06 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,979 | $16,000 | Implemented |
TS0025 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,285 | $50 | Not Implemented |