Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
388
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0695 # 05 Y:2004 | 05 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,056 | $0 | Implemented |
UD0695 # 06 Y:2004 | 06 | 2004 | ADVERTISE PRODUCT OR SERVICE | $7,000 | $-40,240 | Implemented |
UD0695 # 07 Y:2004 | 07 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,434 | $0 | Not Implemented |
UD0695 # 08 Y:2004 | 08 | 2004 | USE MINIMUM SAFE OVEN VENTILATION | $2,564 | $0 | Implemented |
UD0695 # 09 Y:2004 | 09 | 2004 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $2,331 | $175 | Implemented |
UD0695 # 10 Y:2004 | 10 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,110 | $0 | Implemented |
UD0695 # 11 Y:2004 | 11 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $784 | $0 | Implemented |
UD0695 # 12 Y:2004 | 12 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $729 | $0 | Implemented |
UD0695 # 13 Y:2004 | 13 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $397 | $756 | Implemented |
UD0695 # 14 Y:2004 | 14 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $420 | $340 | Not Implemented |
UD0695 # 15 Y:2004 | 15 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $339 | $0 | Implemented |
UD0695 # 16 Y:2004 | 16 | 2004 | DISCONNECT BALLASTS | $327 | $7 | Implemented |
UD0695 # 17 Y:2004 | 17 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $237 | $213 | Implemented |
UD0677 # 01 Y:2003 | 01 | 2003 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $34,103 | $28,000 | Not Implemented |
UD0677 # 02 Y:2003 | 02 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $21,861 | $489 | Not Implemented |
UD0677 # 03 Y:2003 | 03 | 2003 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $18,425 | $0 | Implemented |
UD0677 # 04 Y:2003 | 04 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,186 | $72,000 | Not Implemented |
UD0677 # 05 Y:2003 | 05 | 2003 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $17,000 | $20,000 | Implemented |
UD0677 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,580 | $53,130 | Implemented |
UD0677 # 07 Y:2003 | 07 | 2003 | DISCONNECT BALLASTS | $3,557 | $297 | Not Implemented |
UD0677 # 08 Y:2003 | 08 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,700 | $470 | Implemented |
UD0677 # 09 Y:2003 | 09 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,135 | $400 | Implemented |
UD0677 # 10 Y:2003 | 10 | 2003 | INSULATE BARE EQUIPMENT | $1,019 | $252 | Not Implemented |
UD0677 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $737 | $200 | Implemented |
UD0677 # 12 Y:2003 | 12 | 2003 | ADD AREA LIGHTING SWITCHES | $344 | $820 | Not Implemented |