Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
400
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0231 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $466 | $90 | Not Implemented |
MO0231 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,184 | $80 | Not Implemented |
MO0231 # 07 Y:1998 | 07 | 1998 | USE SYNTHETIC LUBRICANT | $261 | $178 | Not Implemented |
MO0231 # 08 Y:1998 | 08 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $990 | $1,872 | Implemented |
MO0231 # 09 Y:1998 | 09 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $205 | $0 | Implemented |
MO0231 # 10 Y:1998 | 10 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,947 | $5,800 | Implemented |
KU0462 # 01 Y:1996 | 01 | 1996 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $28,125 | $359 | Implemented |
KU0462 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,852 | $312 | Implemented |
KU0462 # 03 Y:1996 | 03 | 1996 | TREAT AND REUSE RINSE WATERS | $6,559 | $3,041 | Implemented |
KU0462 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $5,219 | $1,450 | Implemented |
KU0462 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,755 | $205 | Implemented |
KU0462 # 06 Y:1996 | 06 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,934 | $2,566 | Implemented |
KU0462 # 07 Y:1996 | 07 | 1996 | USE SYNTHETIC LUBRICANT | $1,255 | $299 | Implemented |
KU0462 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $393 | $600 | Not Implemented |
KU0462 # 09 Y:1996 | 09 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $353 | $42 | Implemented |
MO0151 # 01 Y:1995 | 01 | 1995 | USE RADIANT HEATER FOR SPOT HEATING | $27,601 | $17,901 | Not Implemented |
MO0151 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,472 | $15,370 | Implemented |
MO0151 # 03 Y:1995 | 03 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $530 | $25 | Not Implemented |
MO0151 # 04 Y:1995 | 04 | 1995 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $9,918 | $2,845 | Not Implemented |
MO0151 # 05 Y:1995 | 05 | 1995 | USE PLASTIC PALLETS INSTEAD OF WOOD | $38,520 | $36,113 | Not Implemented |
KU0446 # 01 Y:1994 | 01 | 1994 | CONVERT TO ELECTROSTATIC POWDER COATING | $38,324 | $12,000 | Not Implemented |
KU0446 # 02 Y:1994 | 02 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,466 | $2,616 | Not Implemented |
KU0446 # 03 Y:1994 | 03 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,601 | $1,600 | Not Implemented |
KU0446 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,291 | $300 | Implemented |
KU0446 # 05 Y:1994 | 05 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,038 | $10 | Not Implemented |