Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
48
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW2203 # 05 Y:2022 | 05 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $262,732 | $1,628,434 | Not Implemented |
UW2203 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,676 | $7,295 | Not Implemented |
UW2203 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $3,397 | $1,678 | Not Implemented |
UW2203 # 01 Y:2022 | 01 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,698 | $0 | Not Implemented |
UW2203 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,500 | $10,782 | Not Implemented |
OR0603 # 05 Y:2013 | 05 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $73,635 | $1,475,828 | Not Implemented |
OR0603 # 04 Y:2013 | 04 | 2013 | USE SOLAR HEAT TO MAKE ELECTRICTY | $8,411 | $293,900 | Not Implemented |
OR0603 # 03 Y:2013 | 03 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,936 | $0 | Implemented |
OR0603 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $11,386 | $5,275 | Not Implemented |
OR0603 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,204 | $0 | Implemented |
OR0393 # 01 Y:2001 | 01 | 2001 | MODIFY WORKLOAD | $100,000 | $15,300 | n/a |
OR0393 # 02 Y:2001 | 02 | 2001 | ELIMINATE/REDUCE AN OPERATION | $1,120,240 | $662,000 | n/a |
OR0393 # 03 Y:2001 | 03 | 2001 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,734 | $1,500 | n/a |
OR0393 # 04 Y:2001 | 04 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $13,247 | $17,800 | n/a |
OR0393 # 05 Y:2001 | 05 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,716 | $26,090 | n/a |
OR0375 # 05 Y:2000 | 05 | 2000 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $45,562 | $2,451 | Implemented |
OR0375 # 04 Y:2000 | 04 | 2000 | REDUCE SCRAP PRODUCTION | $81,000 | $21,000 | Not Implemented |
OR0375 # 06 Y:2000 | 06 | 2000 | REDUCE SCRAP PRODUCTION | $12,255 | $0 | Not Implemented |
OR0375 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $29,778 | $20,000 | Implemented |
OR0375 # 03 Y:2000 | 03 | 2000 | OPTIMIZE PLANT POWER FACTOR | $2,848 | $9,500 | Not Implemented |
OR0375 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,770 | $0 | Implemented |
OR0330 # 05 Y:1998 | 05 | 1998 | OPTIMIZE PLANT POWER FACTOR | $10,538 | $14,800 | Not Implemented |
OR0330 # 01 Y:1998 | 01 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $335,710 | $438,500 | Not Implemented |
OR0330 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,900 | $0 | Implemented |
OR0330 # 03 Y:1998 | 03 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $690 | $0 | Not Implemented |