Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
109
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0169 # 05 Y:1989 | 05 | 1989 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $460 | $87 | Implemented |
MA0166 # 02 Y:1989 | 02 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,628 | $3,450 | Not Implemented |
MA0168 # 01 Y:1989 | 01 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $14,558 | $10,000 | Not Implemented |
MA0166 # 01 Y:1989 | 01 | 1989 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $19,320 | $18,000 | Not Implemented |
MA0168 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,218 | $0 | Implemented |
MA0168 # 03 Y:1989 | 03 | 1989 | INSTALL SET-BACK TIMERS | $228 | $195 | Not Implemented |
MA0166 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,497 | $908 | Not Implemented |
MA0166 # 05 Y:1989 | 05 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $21,230 | $7,913 | Not Implemented |
MA0166 # 04 Y:1989 | 04 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $842 | $1,700 | Not Implemented |
MA0166 # 03 Y:1989 | 03 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,130 | $180 | Implemented |
CO0169 # 06 Y:1989 | 06 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,270 | $250 | Implemented |
CO0169 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $280 | $410 | Implemented |
CO0169 # 03 Y:1989 | 03 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $1,770 | $2,550 | Implemented |
CO0169 # 02 Y:1989 | 02 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,592 | $455 | Implemented |
CO0169 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,441 | $2,000 | Implemented |
MA0168 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $475 | $305 | Not Implemented |
MA0168 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,362 | $570 | Implemented |
MA0168 # 06 Y:1989 | 06 | 1989 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,664 | $2,700 | Not Implemented |
KU0294 # 06 Y:1989 | 06 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $526 | $200 | Implemented |
KU0294 # 02 Y:1989 | 02 | 1989 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $16,418 | $15,000 | Not Implemented |
KU0294 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $1,104 | $600 | Implemented |
KU0294 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,153 | $4,100 | Implemented |
KU0294 # 07 Y:1989 | 07 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $579 | $0 | Implemented |
KU0294 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $903 | $472 | Implemented |
KU0294 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,667 | $8,200 | Not Implemented |