Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

131

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0428 # 04 Y:2009 04 2009 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,371 $2,260 Not Implemented
UF0428 # 03 Y:2009 03 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,980 $5,895 Implemented
UF0428 # 02 Y:2009 02 2009 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,365 $0 Implemented
UF0428 # 05 Y:2009 05 2009 INSTALL OCCUPANCY SENSORS $872 $1,971 Implemented
UF0428 # 06 Y:2009 06 2009 INSTALL COMMON HEADER ON COMPRESSORS $674 $0 Not Implemented
UF0428 # 09 Y:2009 09 2009 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $25,086 $0 Implemented
UF0428 # 07 Y:2009 07 2009 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $4,285 $0 Implemented
UF0428 # 08 Y:2009 08 2009 OPTIMIZE PLANT POWER FACTOR $44,818 $3,326 Not Implemented
UF0428 # 01 Y:2009 01 2009 MINIMIZE USE OF RAGS THROUGH WORKER TRAINING $1,734 $0 Implemented
MZ0041 # 03 Y:2009 03 2009 INSTALL OCCUPANCY SENSORS $1,693 $1,780 Implemented
MZ0041 # 01 Y:2009 01 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $45,616 $42,000 Implemented
MZ0041 # 02 Y:2009 02 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $60,170 $43,800 Implemented
CO0626 # 04 Y:2009 04 2009 USE PHOTOCELL CONTROLS $2,350 $620 Not Implemented
CO0626 # 03 Y:2009 03 2009 USE SOLAR HEAT TO MAKE ELECTRICTY $5,100 $45,500 Not Implemented
CO0626 # 02 Y:2009 02 2009 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,900 $0 Not Implemented
CO0626 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $46,520 $7,500 Implemented
CO0626 # 05 Y:2009 05 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,140 $360 Not Implemented
CO0626 # 06 Y:2009 06 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $370 $780 Not Implemented
AM0563 # 01 Y:2009 01 2009 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $29,000 $52,000 Not Implemented
AM0563 # 02 Y:2009 02 2009 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $6,577 $3,720 Not Implemented
AM0563 # 03 Y:2009 03 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,075 $1,260 Implemented
AM0563 # 04 Y:2009 04 2009 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,040 $1,134 Not Implemented
AM0563 # 05 Y:2009 05 2009 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $885 $610 Not Implemented
LL0317 # 04 Y:2009 04 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $637 $623 Implemented
LL0317 # 05 Y:2009 05 2009 INSTALL OCCUPANCY SENSORS $335 $90 Not Implemented