Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

150

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AT0110 # 09 Y:1988 09 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $705 $1,500 Implemented
AT0110 # 10 Y:1988 10 1988 IMPROVE LUBRICATION PRACTICES $994 $0 Not Implemented
AT0110 # 11 Y:1988 11 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $622 $0 Implemented
OR0026 # 01 Y:1988 01 1988 INSTALL SET-BACK TIMERS $1,607 $0 Not Implemented
OR0026 # 02 Y:1988 02 1988 INSTALL TIMERS AND/OR THERMOSTATS $28,590 $1,000 Implemented
OR0026 # 03 Y:1988 03 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $382 $100 Not Implemented
OR0026 # 04 Y:1988 04 1988 INSULATE BARE EQUIPMENT $2,666 $3,230 Implemented
OR0026 # 05 Y:1988 05 1988 RECOVER AND REUSE COOLING WATER $702 $2,050 Implemented
OK0260 # 01 Y:1988 01 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $604 $0 Not Implemented
OK0260 # 02 Y:1988 02 1988 RECOVER WASTE HEAT FROM EQUIPMENT $3,473 $525 Not Implemented
OK0260 # 04 Y:1988 04 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $13,831 $275 Not Implemented
OK0260 # 05 Y:1988 05 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,927 $1,500 Not Implemented
OK0260 # 06 Y:1988 06 1988 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,063 $8,400 Not Implemented
OK0260 # 07 Y:1988 07 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $822 $740 Not Implemented
OK0260 # 08 Y:1988 08 1988 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $3,618 $1,200 Not Implemented
MA0120 # 01 Y:1988 01 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,682 $70 Not Implemented
MA0120 # 02 Y:1988 02 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $870 $542 Not Implemented
MA0120 # 03 Y:1988 03 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $962 $231 Not Implemented
MA0120 # 04 Y:1988 04 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $25,643 $42,500 Not Implemented
MA0120 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,063 $9,516 Not Implemented
MA0120 # 06 Y:1988 06 1988 INSTALL TIMERS AND/OR THERMOSTATS $2,845 $1,275 Not Implemented
MA0120 # 07 Y:1988 07 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $36,657 $46,930 Not Implemented
MA0120 # 09 Y:1988 09 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,073 $295 Not Implemented
MA0120 # 10 Y:1988 10 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,650 $6,000 Not Implemented
MA0120 # 11 Y:1988 11 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $15,844 $0 Not Implemented