Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
201
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0425 # 01 Y:2002 | 01 | 2002 | $58,500 | $120,000 | n/a | |
WI0425 # 02 Y:2002 | 02 | 2002 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $11,400 | $2,000 | n/a |
WI0425 # 03 Y:2002 | 03 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,750 | $4,800 | n/a |
WI0425 # 04 Y:2002 | 04 | 2002 | COVER OPEN TANKS | $4,508 | $1,512 | n/a |
WI0425 # 05 Y:2002 | 05 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $931 | $912 | n/a |
WI0425 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $704 | $1,496 | n/a |
WI0425 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $244 | $0 | n/a |
UF0300 # 01 Y:2002 | 01 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,724 | $25,919 | n/a |
UF0300 # 02 Y:2002 | 02 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,536 | $0 | n/a |
UF0300 # 03 Y:2002 | 03 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $152,665 | $117,000 | n/a |
UF0300 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,740 | $290 | n/a |
UF0300 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $1,960 | $518 | n/a |
UF0300 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $106,637 | $10,907 | n/a |
UF0300 # 07 Y:2002 | 07 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $931 | $1,895 | n/a |
CO0503 # 01 Y:2002 | 01 | 2002 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $51,590 | $6,250 | Implemented |
CO0503 # 02 Y:2002 | 02 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $25,940 | $0 | Implemented |
CO0503 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,053 | $0 | Not Implemented |
CO0503 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,310 | $430 | Implemented |
CO0503 # 05 Y:2002 | 05 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,730 | $870 | Not Implemented |
CO0503 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $2,760 | $3,360 | Not Implemented |
CO0503 # 07 Y:2002 | 07 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $498 | $946 | Implemented |
CO0503 # 08 Y:2002 | 08 | 2002 | USE PHOTOCELL CONTROLS | $2,160 | $2,040 | Not Implemented |
MI0038 # 01 Y:2002 | 01 | 2002 | $190,000 | $100,000 | Not Implemented | |
MI0038 # 02 Y:2002 | 02 | 2002 | $18,650 | $26,450 | Implemented | |
MI0038 # 03 Y:2002 | 03 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,094 | $4,500 | Not Implemented |