Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 361 | Electric Distribution Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0848 # 10 Y:2012 | 10 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $834 | $600 | Not Implemented |
UD0848 # 03 Y:2012 | 03 | 2012 | MINIMIZE WATER USAGE | $1,496 | $1,000 | Not Implemented |
UD0848 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,519 | $5,000 | Implemented |
UD0848 # 01 Y:2012 | 01 | 2012 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $550 | $1,000 | Not Implemented |
UD0848 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,458 | $0 | Not Implemented |
UD0848 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $239 | $0 | Not Implemented |
UD0848 # 06 Y:2012 | 06 | 2012 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $3,962 | $1,000 | Not Implemented |
UD0848 # 07 Y:2012 | 07 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,543 | $0 | Implemented |
UD0848 # 08 Y:2012 | 08 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,209 | $1,000 | Not Implemented |
UD0848 # 09 Y:2012 | 09 | 2012 | REDUCE VENTILATION AIR | $882 | $300 | Implemented |
UD0251 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $882 | $300 | Implemented |
UD0251 # 06 Y:1988 | 06 | 1988 | SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS | $311 | $500 | Not Implemented |
UD0251 # 04 Y:1988 | 04 | 1988 | REDESIGN PROCESS | $2,282 | $1,500 | Not Implemented |
UD0251 # 03 Y:1988 | 03 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,853 | $16,000 | Not Implemented |
UD0251 # 02 Y:1988 | 02 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,275 | $0 | Implemented |
UD0251 # 01 Y:1988 | 01 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,500 | $15,000 | Implemented |
UD0137 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $809 | $1,894 | Not Implemented |
UD0137 # 01 Y:1984 | 01 | 1984 | INSULATE BARE EQUIPMENT | $6,700 | $3,000 | Implemented |
UD0085 # 02 Y:1983 | 02 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,015 | $200 | Not Implemented |
UD0085 # 03 Y:1983 | 03 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,059 | $12,000 | Not Implemented |
UD0085 # 01 Y:1983 | 01 | 1983 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $142 | $0 | Not Implemented |
UD0049 # 05 Y:1982 | 05 | 1982 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $7,008 | $7,500 | Implemented |
UD0049 # 04 Y:1982 | 04 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $14,665 | $163,485 | Implemented |
UD0049 # 03 Y:1982 | 03 | 1982 | REDUCE GLAZED AREAS IN BUILDINGS | $28,537 | $40,346 | Implemented |
UD0049 # 02 Y:1982 | 02 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $773 | $0 | Implemented |