Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

51

matching recommendations
Reset
SIC 361 Electric Distribution Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0385 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $872 $1,643 Implemented
NC0385 # 07 Y:2009 07 2009 USE PHOTOCELL CONTROLS $213 $200 Implemented
NC0196 # 07 Y:2000 07 2000 METER WASTE WATER $4,843 $15,000 Not Implemented
NC0196 # 06 Y:2000 06 2000 REVISE SMOKE CLEANUP FROM OPERATIONS $6,218 $8,400 Not Implemented
NC0196 # 05 Y:2000 05 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,438 $10,000 Implemented
NC0196 # 04 Y:2000 04 2000 OPERATE DISTILLATION COLUMNS EFFICIENTLY $292 $1,100 Not Implemented
NC0196 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $8,142 $5,000 Not Implemented
NC0196 # 02 Y:2000 02 2000 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,495 $100 Implemented
NC0196 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $411 $1,080 Not Implemented
NC0157 # 02 Y:1999 02 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,307 $240 Not Implemented
NC0157 # 09 Y:1999 09 1999 MODIFY STARTUP/SHUTDOWN TIMES $3,193 $0 Implemented
NC0157 # 08 Y:1999 08 1999 ADD ADDITIONAL PRODUCTION SHIFT $100,000 $1,000 Not Implemented
NC0157 # 07 Y:1999 07 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $8,000 $200 Implemented
NC0157 # 06 Y:1999 06 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,015 $3,000 Implemented
NC0157 # 05 Y:1999 05 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $17,776 $20,000 Not Implemented
NC0157 # 04 Y:1999 04 1999 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $98,761 $465,000 Not Implemented
NC0157 # 03 Y:1999 03 1999 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $6,654 $2,000 Not Implemented
NC0157 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,968 $1,500 Not Implemented
NC0120 # 08 Y:1997 08 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,063 $5,200 Implemented
NC0120 # 07 Y:1997 07 1997 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $965 $610 Not Implemented
NC0120 # 06 Y:1997 06 1997 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,834 $2,500 Not Implemented
NC0120 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $3,005 $0 Implemented
NC0120 # 04 Y:1997 04 1997 RECOVER WASTE HEAT FROM EQUIPMENT $2,893 $1,300 Not Implemented
NC0120 # 03 Y:1997 03 1997 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,624 $320 Implemented
NC0120 # 02 Y:1997 02 1997 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $3,966 $2,000 Not Implemented