Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
739
matching recommendationsSIC | 361 | Electric Distribution Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0094 # 01 Y:2012 | 01 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,057 | $1,160 | Implemented |
MZ0094 # 02 Y:2012 | 02 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,672 | $3,000 | Not Implemented |
MZ0094 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,711 | $27,900 | Implemented |
MZ0094 # 04 Y:2012 | 04 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $621 | $0 | Implemented |
MZ0094 # 05 Y:2012 | 05 | 2012 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $6,785 | $30,700 | Implemented |
MZ0094 # 06 Y:2012 | 06 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $12,505 | $14,400 | Not Implemented |
MZ0094 # 07 Y:2012 | 07 | 2012 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,836 | $900 | Implemented |
AM0609 # 01 Y:2012 | 01 | 2012 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $98,005 | $5,200 | Not Implemented |
AM0609 # 02 Y:2012 | 02 | 2012 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $37,900 | $400 | Not Implemented |
AM0609 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $44,215 | $2,000 | Not Implemented |
AM0609 # 04 Y:2012 | 04 | 2012 | OPTIMIZE PLANT POWER FACTOR | $24,800 | $47,800 | Not Implemented |
AM0609 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,480 | $23,500 | Not Implemented |
AM0609 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,600 | $0 | Not Implemented |
AM0609 # 07 Y:2012 | 07 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $8,950 | $500 | Not Implemented |
AM0609 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $120 | $40 | Not Implemented |
UD0848 # 01 Y:2012 | 01 | 2012 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $550 | $1,000 | Not Implemented |
UD0848 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,519 | $5,000 | Implemented |
UD0848 # 03 Y:2012 | 03 | 2012 | MINIMIZE WATER USAGE | $1,496 | $1,000 | Not Implemented |
UD0848 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,458 | $0 | Not Implemented |
UD0848 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $239 | $0 | Not Implemented |
UD0848 # 06 Y:2012 | 06 | 2012 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $3,962 | $1,000 | Not Implemented |
UD0848 # 07 Y:2012 | 07 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $13,543 | $0 | Implemented |
UD0848 # 08 Y:2012 | 08 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,209 | $1,000 | Not Implemented |
UD0848 # 09 Y:2012 | 09 | 2012 | REDUCE VENTILATION AIR | $882 | $300 | Implemented |
UD0848 # 10 Y:2012 | 10 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $834 | $600 | Not Implemented |