Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsSIC | 361 | Electric Distribution Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TR0009 # 06 Y:2018 | 06 | 2018 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,315 | $14,000 | Implemented |
TR0009 # 05 Y:2018 | 05 | 2018 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $17,718 | $3,748 | Not Implemented |
TR0009 # 04 Y:2018 | 04 | 2018 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $2,987 | $15,373 | Implemented |
TR0009 # 03 Y:2018 | 03 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $814 | $0 | Not Implemented |
TR0009 # 02 Y:2018 | 02 | 2018 | RECYCLE FLUORESCENT LAMPS | $6,608 | $13,260 | Implemented |
TR0009 # 01 Y:2018 | 01 | 2018 | OPTIMIZE PLANT POWER FACTOR | $3,043 | $12,500 | Not Implemented |
WM0120 # 10 Y:2018 | 10 | 2018 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $660 | $405 | Not Implemented |
WM0120 # 13 Y:2018 | 13 | 2018 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $135 | $328 | Not Implemented |
WM0120 # 12 Y:2018 | 12 | 2018 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $258 | $0 | Not Implemented |
WM0120 # 11 Y:2018 | 11 | 2018 | TURN OFF EQUIPMENT WHEN NOT IN USE | $408 | $0 | Not Implemented |
WM0120 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,818 | $35,678 | Implemented |
WM0120 # 09 Y:2018 | 09 | 2018 | USE PHOTOCELL CONTROLS | $793 | $1,120 | Not Implemented |
WM0120 # 08 Y:2018 | 08 | 2018 | INSTALL OCCUPANCY SENSORS | $1,092 | $1,439 | Not Implemented |
WM0120 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,377 | $2,251 | Implemented |
WM0120 # 06 Y:2018 | 06 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,903 | $5,577 | Not Implemented |
WM0120 # 05 Y:2018 | 05 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,335 | $22,000 | Not Implemented |
WM0120 # 04 Y:2018 | 04 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $13,376 | $48,514 | Not Implemented |
WM0120 # 03 Y:2018 | 03 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $13,520 | $0 | Not Implemented |
WM0120 # 02 Y:2018 | 02 | 2018 | USE RADIANT HEATER FOR SPOT HEATING | $18,564 | $28,796 | Not Implemented |