Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
386
matching recommendationsSIC | 3613 | Switchgear And Switchboard Apparatus |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0236 # 03 Y:1987 | 03 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $241 | $80 | Implemented |
OK0236 # 04 Y:1987 | 04 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $2,644 | $3,300 | Implemented |
OK0236 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $283 | $0 | Implemented |
OK0236 # 06 Y:1987 | 06 | 1987 | COMBINE UTILITY METERS | $768 | $520 | Implemented |
OK0236 # 07 Y:1987 | 07 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,280 | $820 | Implemented |
WI0004 # 04 Y:1987 | 04 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,838 | $13,000 | Not Implemented |
WI0004 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,551 | $549 | Implemented |
WI0004 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $224 | $0 | Not Implemented |
WI0004 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $448 | $0 | Implemented |
WI0004 # 05 Y:1987 | 05 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $282 | $842 | Not Implemented |
WI0004 # 06 Y:1987 | 06 | 1987 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $927 | $2,100 | Implemented |
TN0308 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,834 | $0 | Not Implemented |
TN0308 # 02 Y:1987 | 02 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,468 | $16,872 | Not Implemented |
TN0308 # 03 Y:1987 | 03 | 1987 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $2,858 | $3,500 | Not Implemented |
TN0308 # 04 Y:1987 | 04 | 1987 | INSULATE BARE EQUIPMENT | $603 | $1,440 | Implemented |
TN0308 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,709 | $165 | Implemented |
TN0308 # 06 Y:1987 | 06 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $950 | $470 | Implemented |
TN0308 # 07 Y:1987 | 07 | 1987 | OPTIMIZE PLANT POWER FACTOR | $1,764 | $6,800 | Implemented |
OK0175 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $678 | $1,252 | Implemented |
OK0175 # 02 Y:1985 | 02 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,344 | $3,461 | Not Implemented |
OK0175 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $748 | $400 | Implemented |
OK0175 # 04 Y:1985 | 04 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,056 | $330 | Not Implemented |
OK0175 # 05 Y:1985 | 05 | 1985 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $1,954 | $4,000 | Implemented |
OK0175 # 06 Y:1985 | 06 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,146 | $35,020 | Not Implemented |
TN0221 # 01 Y:1984 | 01 | 1984 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $4,406 | $7,000 | Not Implemented |