Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,337
matching recommendationsSIC | 362 | Electrical Industrial Apparatus |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0528 # 03 Y:2014 | 03 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,799 | $150 | Implemented |
NC0528 # 04 Y:2014 | 04 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,209 | $1,935 | Implemented |
NC0528 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $917 | $650 | Not Implemented |
NC0528 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $612 | $754 | Implemented |
NC0528 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $726 | $224 | Not Implemented |
NC0528 # 08 Y:2014 | 08 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $471 | $275 | Not Implemented |
NC0528 # 09 Y:2014 | 09 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,119 | $100 | Implemented |
MZ0157 # 01 Y:2014 | 01 | 2014 | INSULATE BARE EQUIPMENT | $571 | $601 | Not Implemented |
MZ0157 # 02 Y:2014 | 02 | 2014 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $1,077 | $10,750 | Implemented |
MZ0157 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,149 | $30,133 | Implemented |
MZ0157 # 04 Y:2014 | 04 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $2,223 | $17,400 | Not Implemented |
MZ0157 # 05 Y:2014 | 05 | 2014 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $3,840 | $9,600 | Implemented |
SU0364 # 01 Y:2014 | 01 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,567 | $0 | Not Implemented |
SU0364 # 02 Y:2014 | 02 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $13,052 | $0 | Implemented |
SU0364 # 03 Y:2014 | 03 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $296 | $0 | Not Implemented |
SU0364 # 04 Y:2014 | 04 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $695 | $870 | Not Implemented |
SU0364 # 05 Y:2014 | 05 | 2014 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $533 | $704 | Implemented |
SU0364 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,728 | $27,708 | Implemented |
SU0364 # 07 Y:2014 | 07 | 2014 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $122 | $364 | Not Implemented |
SU0364 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $296 | $1,020 | Implemented |
SU0364 # 09 Y:2014 | 09 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $175 | $620 | Not Implemented |
SU0364 # 10 Y:2014 | 10 | 2014 | ELIMINATE/REDUCE AN OPERATION | $2,217 | $8,640 | Not Implemented |
OK0891 # 01 Y:2014 | 01 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,349 | $17,104 | Not Implemented |
OK0891 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,744 | $13,618 | Implemented |
OK0891 # 03 Y:2014 | 03 | 2014 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,714 | $832 | Implemented |