Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
92
matching recommendationsSIC | 3624 | Carbon And Graphite Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0361 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,204 | $2,000 | Implemented |
WV0361 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $0 | Implemented |
WV0361 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $115,865 | $26,750 | Not Implemented |
WV0361 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $13,999 | $13,900 | Not Implemented |
WV0361 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $42,691 | $13,780 | Implemented |
WV0361 # 06 Y:2007 | 06 | 2007 | USE PHOTOCELL CONTROLS | $1,311 | $430 | Implemented |
WV0361 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,012 | $15,100 | Not Implemented |
WV0361 # 08 Y:2007 | 08 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $657 | $276 | Implemented |
OK0736 # 06 Y:2006 | 06 | 2006 | USE PHOTOCELL CONTROLS | $3,268 | $225 | Not Implemented |
OK0736 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,322 | $1,267 | Implemented |
OK0736 # 04 Y:2006 | 04 | 2006 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $8,438 | $765 | Implemented |
OK0736 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $224,746 | $154,440 | Implemented |
OK0736 # 03 Y:2006 | 03 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $29,250 | $20,340 | Implemented |
OK0736 # 02 Y:2006 | 02 | 2006 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $447,023 | $299,500 | Not Implemented |
WV0343 # 02 Y:2006 | 02 | 2006 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,096,704 | $1,539,100 | Not Implemented |
WV0343 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $21,955 | $3,114 | Implemented |
WV0343 # 06 Y:2006 | 06 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $4,236 | $635 | Implemented |
WV0343 # 01 Y:2006 | 01 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,166,408 | $1,460,000 | Not Implemented |
WV0343 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,918 | $0 | Implemented |
WV0343 # 05 Y:2006 | 05 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,836 | $2,255 | Not Implemented |
WI0489 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $481 | $100 | Implemented |
WI0489 # 04 Y:2005 | 04 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,606 | $3,000 | Not Implemented |
WI0489 # 01 Y:2005 | 01 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $8,655 | $1,600 | Implemented |
WI0489 # 05 Y:2005 | 05 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,494 | $2,314 | Implemented |
WI0489 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $782 | $0 | Implemented |