Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
346
matching recommendationsSIC | 3625 | Relays And Industrial Controls |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ST0035 # 09 Y:1985 | 09 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,520 | $537 | Not Implemented |
ST0035 # 10 Y:1985 | 10 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,918 | $3,089 | Not Implemented |
ST0035 # 11 Y:1985 | 11 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,508 | $350 | Not Implemented |
ST0035 # 12 Y:1985 | 12 | 1985 | REDUCE GLAZED AREAS IN BUILDINGS | $1,130 | $4,848 | Not Implemented |
ST0035 # 13 Y:1985 | 13 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $9,670 | $136 | Not Implemented |
ST0035 # 14 Y:1985 | 14 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $25,586 | $3,500 | Implemented |
OK0048 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $398 | $265 | Not Implemented |
OK0048 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $126 | $738 | Not Implemented |
OK0048 # 03 Y:1982 | 03 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $35 | $17 | Implemented |
OK0048 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,338 | $400 | Not Implemented |
TN0128 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,431 | $1,971 | Not Implemented |
TN0128 # 02 Y:1982 | 02 | 1982 | COVER OPEN TANKS | $2,342 | $400 | Not Implemented |
TN0128 # 03 Y:1982 | 03 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,660 | $4,250 | Not Implemented |
UD0039 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,698 | $1,557 | Implemented |
UD0039 # 02 Y:1982 | 02 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $480 | $0 | Implemented |
UD0039 # 03 Y:1982 | 03 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $357 | $300 | Implemented |
UD0039 # 04 Y:1982 | 04 | 1982 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $7,302 | $13,500 | Implemented |
UD0039 # 05 Y:1982 | 05 | 1982 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $1,253 | $7,000 | Implemented |
GT0118 # 01 Y:1982 | 01 | 1982 | AIR CONDITION ONLY SPACE NECESSARY | $5,952 | $573 | Not Implemented |
GT0118 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,187 | $608 | Not Implemented |
GT0118 # 04 Y:1982 | 04 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,676 | $198 | Not Implemented |