Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

34

matching recommendations
Reset
SIC 3625 Relays And Industrial Controls
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0102 # 02 Y:1994 02 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,055 $300 Implemented
IA0102 # 01 Y:1994 01 1994 INSTALL OCCUPANCY SENSORS $1,494 $1,840 Implemented
IA0102 # 06 Y:1994 06 1994 INSTALL TIMERS AND/OR THERMOSTATS $689 $130 Not Implemented
IA0102 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $342 $700 Not Implemented
IA0102 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $861 $175 Implemented
IA0102 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,169 $850 Not Implemented
IA0082 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,372 $6,405 Implemented
IA0082 # 10 Y:1994 10 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $121 $188 Not Implemented
IA0082 # 09 Y:1994 09 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $171 $20 Implemented
IA0082 # 08 Y:1994 08 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $634 $1,200 Implemented
IA0082 # 07 Y:1994 07 1994 OPTIMIZE PLANT POWER FACTOR $1,520 $5,265 Implemented
IA0082 # 06 Y:1994 06 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $621 $25 Not Implemented
IA0082 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,898 $550 Implemented
IA0082 # 04 Y:1994 04 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,687 $8,790 Not Implemented
IA0082 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $1,087 $693 Implemented
IA0082 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,862 $1,656 Not Implemented
TN0513 # 03 Y:1994 03 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $3,733 $0 Not Implemented
TN0513 # 04 Y:1994 04 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,076 $3,350 Not Implemented
TN0513 # 11 Y:1994 11 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $169 $470 Not Implemented
TN0513 # 05 Y:1994 05 1994 INSULATE BARE EQUIPMENT $168 $95 Implemented
TN0513 # 06 Y:1994 06 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $638 $480 Implemented
TN0513 # 07 Y:1994 07 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $431 $1,300 Not Implemented
TN0513 # 08 Y:1994 08 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $338 $570 Not Implemented
TN0513 # 09 Y:1994 09 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $319 $120 Not Implemented
TN0513 # 10 Y:1994 10 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $263 $0 Implemented