Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
206
matching recommendationsSIC | 3629 | Electrical Industrial Apparatus, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0367 # 01 Y:1992 | 01 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $727 | $0 | Not Implemented |
UD0367 # 02 Y:1992 | 02 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,207 | $400 | Not Implemented |
UD0367 # 03 Y:1992 | 03 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $4,588 | $1,800 | Not Implemented |
SD0010 # 01 Y:1991 | 01 | 1991 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $1,469 | $468 | Not Implemented |
SD0010 # 02 Y:1991 | 02 | 1991 | INSULATE BARE EQUIPMENT | $25 | $22 | Not Implemented |
SD0010 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $887 | $832 | Not Implemented |
SD0010 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,661 | $3,360 | Not Implemented |
SD0010 # 05 Y:1991 | 05 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $287 | $600 | Not Implemented |
SD0010 # 06 Y:1991 | 06 | 1991 | INSTALL SET-BACK TIMERS | $1,627 | $3,600 | Not Implemented |
SD0010 # 07 Y:1991 | 07 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $12,712 | $31,740 | Not Implemented |
SD0010 # 08 Y:1991 | 08 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $6,433 | $22,980 | Not Implemented |
SD0010 # 09 Y:1991 | 09 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,188 | $18,000 | Not Implemented |
CO0211 # 01 Y:1991 | 01 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,840 | $250 | Implemented |
CO0211 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,625 | $912 | Implemented |
CO0211 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $970 | $1,600 | Implemented |
CO0211 # 04 Y:1991 | 04 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $460 | $100 | Implemented |
CO0211 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $49 | $145 | Implemented |
MA0120 # 01 Y:1988 | 01 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,682 | $70 | Not Implemented |
MA0120 # 02 Y:1988 | 02 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $870 | $542 | Not Implemented |
MA0120 # 03 Y:1988 | 03 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $962 | $231 | Not Implemented |
MA0120 # 04 Y:1988 | 04 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $25,643 | $42,500 | Not Implemented |
MA0120 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,063 | $9,516 | Not Implemented |
MA0120 # 06 Y:1988 | 06 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $2,845 | $1,275 | Not Implemented |
MA0120 # 07 Y:1988 | 07 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $36,657 | $46,930 | Not Implemented |
MA0120 # 09 Y:1988 | 09 | 1988 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,073 | $295 | Not Implemented |