Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
403
matching recommendationsSIC | 363 | Household Appliances |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0677 # 01 Y:2003 | 01 | 2003 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $34,103 | $28,000 | Not Implemented |
UD0677 # 02 Y:2003 | 02 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $21,861 | $489 | Not Implemented |
UD0677 # 03 Y:2003 | 03 | 2003 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $18,425 | $0 | Implemented |
UD0677 # 04 Y:2003 | 04 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,186 | $72,000 | Not Implemented |
UD0677 # 05 Y:2003 | 05 | 2003 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $17,000 | $20,000 | Implemented |
UD0677 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,580 | $53,130 | Implemented |
UD0677 # 07 Y:2003 | 07 | 2003 | DISCONNECT BALLASTS | $3,557 | $297 | Not Implemented |
UD0677 # 08 Y:2003 | 08 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,700 | $470 | Implemented |
UD0677 # 09 Y:2003 | 09 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,135 | $400 | Implemented |
UD0677 # 10 Y:2003 | 10 | 2003 | INSULATE BARE EQUIPMENT | $1,019 | $252 | Not Implemented |
UD0677 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $737 | $200 | Implemented |
UD0677 # 12 Y:2003 | 12 | 2003 | ADD AREA LIGHTING SWITCHES | $344 | $820 | Not Implemented |
UD0677 # 13 Y:2003 | 13 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $143 | $400 | Not Implemented |
IC0042 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $1,202 | $1,929 | Implemented |
IC0042 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,772 | $5,500 | Implemented |
IC0042 # 02 Y:2002 | 02 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,477 | $0 | Implemented |
IC0042 # 03 Y:2002 | 03 | 2002 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,720 | $0 | Not Implemented |
IC0042 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $818 | $975 | Not Implemented |
IC0042 # 06 Y:2002 | 06 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $407 | $145 | Not Implemented |
IC0042 # 07 Y:2002 | 07 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $1,160 | $435 | Not Implemented |
IC0042 # 08 Y:2002 | 08 | 2002 | INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS | $53,956 | $110,000 | Not Implemented |
MS0178 # 04 Y:2001 | 04 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,493 | $1,893 | Implemented |
MS0178 # 01 Y:2001 | 01 | 2001 | AIR CONDITION ONLY SPACE NECESSARY | $133,472 | $38,250 | Not Implemented |
MS0178 # 02 Y:2001 | 02 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $23,451 | $3,230 | Not Implemented |
MS0178 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $8,374 | $3,053 | Not Implemented |