Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
403
matching recommendationsSIC | 363 | Household Appliances |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0595 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,660 | $480 | Not Implemented |
TN0595 # 06 Y:1996 | 06 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,920 | $4,450 | Not Implemented |
TN0595 # 07 Y:1996 | 07 | 1996 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $2,600 | $0 | Implemented |
TN0595 # 08 Y:1996 | 08 | 1996 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $1,600 | $930 | Not Implemented |
TN0589 # 01 Y:1996 | 01 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $7,441 | $2,160 | Not Implemented |
TN0589 # 02 Y:1996 | 02 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,430 | $2,280 | Implemented |
TN0589 # 03 Y:1996 | 03 | 1996 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $527 | $636 | Not Implemented |
TN0589 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $477 | $90 | Not Implemented |
TN0589 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $130 | $260 | Not Implemented |
OD0042 # 01 Y:1995 | 01 | 1995 | METER WASTE WATER | $32,200 | $717 | Implemented |
OD0042 # 02 Y:1995 | 02 | 1995 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $29,544 | $5,168 | Implemented |
OD0042 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $37,136 | $66,487 | Implemented |
OD0042 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,061 | $3,657 | Implemented |
OD0042 # 05 Y:1995 | 05 | 1995 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $7,916 | $2,449 | Not Implemented |
OD0042 # 06 Y:1995 | 06 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $2,074 | $1,170 | Not Implemented |
OD0042 # 07 Y:1995 | 07 | 1995 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $462 | $20 | Not Implemented |
OK0461 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $257 | $0 | Not Implemented |
OK0461 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,455 | $19,000 | Not Implemented |
OK0461 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,046 | $120 | Implemented |
OK0461 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $993 | $437 | Implemented |
OK0461 # 05 Y:1995 | 05 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $127 | $201 | Not Implemented |
GT0524 # 01 Y:1994 | 01 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,680 | $1,300 | Not Implemented |
GT0524 # 02 Y:1994 | 02 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,160 | $5,030 | Not Implemented |
GT0524 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,250 | $8,000 | Not Implemented |
GT0524 # 04 Y:1994 | 04 | 1994 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,930 | $5,800 | Not Implemented |