Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsSIC | 3633 | Household Laundry Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1026 # 06 Y:2021 | 06 | 2021 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $817 | $0 | Not Implemented |
UD1026 # 05 Y:2021 | 05 | 2021 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $42,343 | $88,894 | Implemented |
UD1026 # 04 Y:2021 | 04 | 2021 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $441,982 | $200,000 | Not Implemented |
UD1026 # 03 Y:2021 | 03 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $58,812 | $45,000 | Not Implemented |
UD1026 # 02 Y:2021 | 02 | 2021 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $174,302 | $45,000 | Implemented |
UD1026 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,601 | $0 | Implemented |
IC0138 # 08 Y:2008 | 08 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $158 | $0 | Implemented |
IC0138 # 09 Y:2008 | 09 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $14,928 | $1,500 | Implemented |
IC0138 # 07 Y:2008 | 07 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,513 | $0 | Implemented |
IC0138 # 06 Y:2008 | 06 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,154 | $0 | Implemented |
IC0138 # 05 Y:2008 | 05 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,556 | $20,784 | Implemented |
IC0138 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,232 | $143,228 | Implemented |
IC0138 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $927 | $3,982 | Implemented |
IC0138 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $422 | $537 | Implemented |
IC0138 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,199 | $66,929 | Implemented |
IA0214 # 07 Y:1999 | 07 | 1999 | ELIMINATE/REDUCE AN OPERATION | $97,749 | $800 | Implemented |
IA0214 # 06 Y:1999 | 06 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $176,000 | $575,000 | Not Implemented |
IA0214 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $14,369 | $4,297 | Not Implemented |
IA0214 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $742 | $764 | Implemented |
IA0214 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $708 | $1,264 | Not Implemented |
IA0214 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,935 | $579 | Not Implemented |
IA0214 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,846 | $13,626 | Implemented |
OK0524 # 02 Y:1997 | 02 | 1997 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $37,293 | $65,478 | Not Implemented |
OK0524 # 09 Y:1997 | 09 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $267 | $450 | Not Implemented |
OK0524 # 08 Y:1997 | 08 | 1997 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $741 | $0 | Not Implemented |